Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco SinePower MSP 702 Bedienungsanleitung Seite 51

Sinus wechselrichter
Vorschau ausblenden Andere Handbücher für SinePower MSP 702:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
_MSP702_MSP2524.book Seite 51 Montag, 18. Januar 2010 4:43 16
SinePower
11.1
Set energy saving mode (Standby)
In energy saving mode, the inverter does not release any voltage, thereby
preserving the battery. If a connected appliance requires power which is
more than the pre-set power value, the inverter reverts to normal operation.
You can switch to energy-saving mode using the DIP switches S1, S2 and
S3 (fig. 3 1, page 4) and set the power value.
The switch positions for your inverter can be found in the following table:
Energy-saving mode up to
MSP 702
MSP 704
Off
15 W
25 W
40 W
50 W
65 W
75 W
85 W
11.2
Switch between 50 Hz and 60 Hz.
The output voltage can be switched between 50 Hz and 60 Hz with the DIP
switch S4 (fig. 3 1, page 4).
e
Warning!
Only adjust the S4 DIP switch when the respective frequency for
the output voltage should be used.
Set the S4 DIP switch (fig. 3 1, page 4) according to the following table:
Output voltage frequency
www.busse-yachtshop.de | info@busse-yachtshop.de
MSP 1012
MSP 2012
MSP 1024
MSP 2024
MSP 1512
MSP 2512
MSP 1524
MSP 2524
Off
20 W
40 W
55 W
75 W
95 W
115 W
135 W
50 Hz
60 Hz
DIP switch
S1
Off
Off
40 W
On
80 W
Off
125 W
On
170 W
Off
210 W
On
245 W
Off
280 W
On
S4 DIP switch
Off
On
Using the inverter
S2
S3
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
On
On
51

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis