Herunterladen Inhalt Inhalt Diese Seite drucken

Possibilities For Insertion; Kitchen Unit With Door - AEG HG755520 Benutzerinformation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

28 www.aeg.com
• None of a parts of the connection ca-
ble can not get a temperature 90 °C.
The blue neutral cable must be con-
nected to the terminal block label with
"N". The brown (or black) phase cable
(fitted in the terminal block contact
marked with "L") must always be con-
nected to the live phase.
8.5 Replacement of the
connection cable
To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
8.6 Building In
min. 55 mm
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.

8.7 Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.
600 mm
min. 100 mm
min. 650 mm
30 mm
560 mm
B
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
A
Removable panel
a)
b)
Space for connections
30 mm
min 20 mm
a
(max 150 mm)
60 mm
b
A