Herunterladen Inhalt Inhalt Diese Seite drucken

Connection With The Mains; Connection Between Devices; Operation; Stand-Alone Operation - EuroLite LED TMH-21.i Twin Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

Connection between devices

On the rear panel, there is a socket (Power Out). Connect the output with the mains input of the next fixture
until all fixtures are connected.
Please note: A maximum of 8 devices may be linked together. After every 8 devices, the fixtures

OPERATION

After you connected the effect to the mains, the LED TMH-21.i Twin starts running. During the Reset, the
motors are trimmed and the device is ready for use afterwards.

Stand-alone operation

In the Stand-alone mode, the LED TMH-21.i Twin can be used without controller.
Disconnect the LED TMH-21.i Twin from the controller and call the internal program. Please refer to the
instructions under Control Board.

Master/Slave-operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LED TMH-21.i Twin you can find an XLR-jack (DMX Out) and an XLR-plug (DMX
In), which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT jack with the DMX IN plug of the next device.
Set the desired Master-mode - „Auto" or „Soun", for the master-device, as described in chapter Control
Board. Set the DMX address 001 for all slave-devices.
International
L
N
must have a renewed connection with the power mains.
25/31
00092157, Version 1.2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis