Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

Connection between devices

On the side panel, there is a socket (Power Out). Connect the output with the mains input of the next fixture
until all fixtures are connected.
Please note: A maximum of 8 devices may be linked together. After every 8 devices, the fixtures must have

OPERATION

After you connected the LED TL-3 TCL 3x3W to the mains, it starts running.
The LED display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP and
DOWN.
The device has three operating modes. It can be operated in Stand Alone Mode via the Control Board, via
optionally available EUROLITE IR-7 remote control or in DMX-controlled mode via every standard DMX
controller.
Please refer to the instructions under Control Board.
International
L
N
a renewed connection with the power mains.
25/32
00080438.DOC, Version 1.1