ATTENTION! Pressure test of the system by higher pressure shall be carried out when the heat exchange
unit is switched off.
ATTENTION! Only clear water shall be filled to a water heating system. It shall meet requirements of
quality in the context of salt, iron, lime content and other.
If necessary to get hot water at a short time then it will be permitted to make water distribution before its entry
to a tank. For this purpose, it is necessary to connect a threeway tap (7) to a pipe of hot line between a top fitting
adapter of a heat transfer device and a outboard tank in a convenient place for you (figures 10).
It is necessary to compact thread connections by plumbing sealant or PTFE-4 band GOST24222-80 (GOST –
national state standard).
8.10. Hot water tank assembly
ATTENTION! Hot water tank is the unit of extra high hazard that is why it is necessary to exercise caution
while being near it.
ATTENTION! «Termofor» company is not responsible for improper fastening of the tank.
ATTENTION! Avoid corrosive substances entering the hot water tank and water heating system.
ATTENTION! It is prohibited to pour water into the empty tank and (or) fill in empty water heating system
(if any) after stove starting up until the full cooling off of the stove and the tank.
Two types of tanks can be used for hot water with the stove «Compact 2013»: «outboard» tank and «samovar»
type.
An outboard tank is fixed on a wall of steam room or washing room in convenience place for a Consumer.
Then, it is connected to a heat transfer device through the use of pipeline (scheme of installation of a water heating
system, see point 8.9). Water in a tank is heated by its circulation through a heat-transfer.
ATTENTION! To avoid injuries and burns it is necessary to provide maximum reliable fastening of the tank
to the wall.
ATTENTION! The wall at which the remote tank is installed shall support the weight of the tank fully filled
in with water.
A tank of «samovar» type is fixed on outlet branch pipe of the chimney. Water is heated by warm of outgoing
flue gases into the chimney.
When water starts to boil cold water shall be added into the tank.
Don't pour the water in tank up to the top because when water starts to boil it may spill over.
ATTENTION! It is prohibited to misuse the tank.
4
1. Chimney
5
2. Heat exchange unit «Kostakan» of «samovar» type
6
3. Stove «Compact 2013»
4. Connection with atmosphere
7
5. Outboard tank for hot water
8
6. Tap for hot water
min 30°
7. Connective pipes
8. Connective pipes
9
9. Tap for water drain
heating system with using the heat exchange unit
«Kostakan» of «samovar» type
Figure 10. Scheme of installation of a water
39