Figure 7. Installation of the stove in inflammable material premise
ATTENTION! It is prohibited to install the stove in the places where the stove will create obstacles for
people moving during evacuation.
ATTENTION! It is necessary to carry out the installation of smoke sensors and gas detectors in the rooms
where the stove is installed.
Mount the stove to the specially prepared place. Make sure that the stove is assembled and installed correctly.
Provided after reading this manual you still have any doubts concerning the stove correct installation you
should consult the stove assembly specialist who is aware of all the aspects of safe and correct installation of stoves.
A scheme of installation of the stove is presented in figure 7. Distance from the door of the combustor till the
wall opposite will be at least 1250 mm. Distance between the top of the stove and an unguarded ceiling will be at
least 1200 mm.
The distance between the stove external surface, flue and wall should be at least:
for unprotected constructions of combustible and fire-resistant materials - 500 mm;
for constructions of non-combustible materials - 380 mm;
for constructions of combustible and fire-resistant materials protected in accordance with clause 7.2 -
380 mm;
Do not install the stove into the niche in a wall or into the fire place.
Distance from the side of a fuel canal till a wall shall be at least 30 mm. If thickness of a wall is 125 mm then a
door of a combustor will have the most correct position.
Wall opening for fuel channel from the level of support feet shall have the following dimensions (height ?
width):
for «Compact 2013» and «Compact 2013 WT» models — 480? 270 mm
for «Compact 2013 Vitra» and «Compact 2013 Vitra WT» models — 545? 410 mm
2
3
130
130
9
380
a metal plate on a heat-insulation material (an
asbestos paper with thickness 10 mm)
wood (inflammable material)
a thermal insulation of a nonflammable material
(haydite/dross/ basalt wool)
bricks and so on (a nonflammable material)
a material of foundation (nonflammable)
1. A sheet in front of a combustor
2. An umbrella
3. Flue with a thermal insulation of type "sandwich
construction"
4. An overlap of a nonflammable material for a roof
5. A roof splicing
6. A hole for used air exhaust
7. Adjustable latches
8. A vertical box
9. A hole for fresh air intake
Âèä À
1
500
495
30 min
35