«sandwich» type of «Termofor» trademark.
In case of connection of the stove to fixed built-in stove pipe or in other cases it is not recommended to deflect
the axis of chimney stack from the vertical line for more than 45°.
ATTENTION! Bath stove and chimney stack assembly shall be carried out by qualified workers from the
specialized construction and installation company in compliance with the requirements of SNIP 41-01-
2003 (construction codes and regulations) or in compliance with technical norms of the country where the
stove will be used.
ATTENTION! It is strictly prohibited to make dismountable the connections of the stove with the stove pipe
or other structural elements of the room.
ATTENTION! In case of fire in the stove pipe shut the dampers of air supply into the fire chamber, leave the
room and immediately call the firemen.
In case of fire in the stove pipe it is necessary to have a clear scheme of actions that shall be elaborated by
consulting the specialist. After the fire in the stove pipe will die down, the stove pipe shall be cleaned and checked
for the destructions. Make sure that there are no flammables around the stove pipe.
8.8. Stoves with heat exchange unit
The stoves with heat exchanger allow the hot water tank placing outside the steam room and set it in the wash
room. «Compact 2013» stoves provide for the use of a heat exchanger of «samovar» type, which is installed on the
chimney outlet. The water thus heated by the exhaust hot gases directed into the chimney, as in the case of
«samovar» type tank.
Exchanger of «samovar» type can be rotated in any direction with its nozzle. Heat exchangers are made of heat-
resistant high-alloy steel with a chromium content not less than 13%.
«Termofor» company recommends using of samovar type heat exchanger «Kostakan» by «Termofor» brand
with «Compact 2013» stove.
8.9. Installation of a water heating system
ATTENTION! Don't connect a heating system to a heat exchange unit.
The general scheme of water heating system mounting with a heat exchanger of «samovar» type is shown in
Figure 10. Components of water heating system are not supplied.
A water heating system consists of:
A heat exchange unit (2) with two fitting adapter;
Connective pipes (pipeline) (8);
An outboard tank (5) for hot water with two fitting adapters for connecting to a heat transfer system and
one fitting adapter for installation of a tap of hot water distribution;
A tap for hot water (6), a threeway tap (7) and a tap for water drain from a system (9).
At the time of installation of a water heating system, a bottom of an outboard tank for hot water shall be over
of a level of a top fitting adapter of a heat transfer device no less than 30 cm.
ATTENTION! At the time of pipelines installation, don't permit its sagging in horizontal segments. It is
recommended to install these pipelines at an angle of up no less than 30°.
ATTENTION! Don't use pipes with work temperature of operation less than +95°C for a water heating
system.
ATTENTION! Don't use connecting elements of a pipe fitting with nominal width less than nominal width
of fitting adapter of a heat exchange unit.
ATTENTION! It is prohibited to exceed the operating pressure in the water heating system for more than
0.05 MPA (0,5 kgs/cm? ) during the use of «Compact 2013» bath stove with the heat exchange unit.