Check on setting

0
set value

Table of DIP-switch functions

14
A
3
88
number of DIP-switch
Air Hockey TYPHOON
Check on setting
• The coin door is opened, and the service
switch
is set to midposition.
• The slide-in unit is pulled, and DIP switch 8 is
set to ON.
• The "start" push-button is held depressed,
and the service switch is pulled.
• The "start" push-button is released.
The following values are indicated on the dis-
play:
"GAMES" display
"A" for indication is displayed.
"GOALS" right display
The corresponding function of DIP switches 1 to
7 is indicated here.
"PLAYING TIME" display
The set value of the indicated DIP switch is
shown here.
"GOALS" left display
A "0" is indicated continuously.
Start push-button
By pressing the "start" push-button, all DIP
switches and programmed values can be indica-
ted in succession on the display.
Table of DIP switch functions
DIP
switch
8 only
Setting indication
1 and 8
coin value channel 1
2 and 8
coin value channel 2
3 and 8
coin value channel 3
4 and 8
value for one game
5 and 8
maximal number of goals
maximal time for
6 and 8
one game
7 and 8
counter mode
Alteration of the programmed values is not possi-
ble in the display mode.
After the check, DIP switch 8 must be
set to OFF.