8. CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the turntable. Please use a soft lint-free and moistened cloth. Never
use alcohol or solvents! For dusting the stylus and the records, use a carbon fiber brush for records (e.g.
item 10608985 carbon fibber brush). There are no serviceable parts inside the device. Maintenance and
service operations are only to be carried out by authorized dealers. Should you need any spare parts, please
use genuine parts. Should you have further questions, please contact your dealer.

8.1 Transport

For dispatching the turntable pay attention that all components of the unit are only packed in their original
packing material and/or are especially secured for transportation.
1. Place the protective cap on the stylus.
2. Secure the tone arm with the locking lever.
3. Unscrew the counterweight for the tone arm by turning it clockwise and pack it separately and secured
for transportation.
4. Remove the turntable platter from the axle and pack it separately and secured for transportation.
5. Please use the original packing box.
CH

9. ACCESSORIES

9.1 Replacement phono cartridge system and stylus

If required, the phono cartridge system or the stylus can easily be replaced. The corresponding replacement
parts are available from the retailer, e. g. the magnetic phono cartridge system S-15 and the matching stylus
S-15 from OMNITRONIC.
1. To change the stylus, pull off the stylus support in forward direction. Put the new stylus on the stylus
system.
2. To change the phono cartridge system, screw off the headshell from the tone arm.
3. Screw off the phono cartridge system from the support and pull off the connection wires.
4. Tightly screw the new phono cartridge system on the support and put on the wires as follows:
white
left channel positive pole
blue
left channel negative pole
red
right channel positive pole
green
right channel negative pole
5. For optimized pick-up the overhang – the distance between the stylus and the axle of the turntable –
should be set to 15 mm. Make sure that the system is centered (correct azimuth) and the screws are
fixed (Fig. 10).
6. After replacing the phono cartridge system, readjust the stylus pressure and the anti-skating value
(chapters 5.3 and 5.4).
Fig. 10 Adjusting the azimuth
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!