Generex CS121 Serie Benutzerhandbuch Seite 71

Werbung

114
U
3 / 4 CNT_PF
115
U
3 / 4 Alarm Battery Bad
116
U
3 / 4 Alarm: On Battery
117
U
3 / 4 Alarm: Battery Low
118
U
3 / 4 Alarm: Battery Depleted
119
U
3 / 4 Alarm: Over temperature
120
U
3 / 4 Alarm: Input Bad
121
U
3 / 4 Alarm: Output Bad
122
U
3 / 4 Alarm: Output Overload
123
U
3 / 4 Alarm: On Bypass
124
U
3 / 4 Alarm: Bypass Bad
125
U
3 / 4 Alarm: Output Off as
requested.
126
U
3 / 4 Alarm: UPS Off as requested. 1 = active; 0 = not active
127
U
3 / 4 Alarm: Charger Failed
128
U
3 / 4 Alarm: UPS Output Off
129
U
3 / 4 Alarm: UPS System Off
130
U
3 / 4 Alarm: Fan Failure
131
U
3 / 4 Alarm: fuse failure
132
U
3 / 4 Alarm: general fault
133
U
3 / 4 Alarm: diagnose test failed
134
U
3 / 4 Alarm: communication lost
135
U
3 / 4 Alarm: awaiting power
136
U
3 / 4 Alarm: shutdown pending
137
U
3 / 4 Alarm: shutdown imminent
138
U
3 / 4 Alarm: test in progress
139
U
3 / 4 AUX Port 1
140
U
3 / 4 AUX Port 2
141
U
3 / 4 AUX Port 3
142
U
3 / 4 AUX Port 4
143
U
3 / 4 Mesurement sensor 1
Section OEM
NEWAVE UPS
139
U
3 / 4 Manual Bypass Switch Closed 0 = open
140
U
3 / 4 OUTPUT_VOLT0
141
U
3 / 4 OUTPUT_VOLT1
142
U
3 / 4 OUTPUT_VOLT2
143
U
3 / 4 OutputCurrent Phase A * 10
144
U
3 / 4 OutputCurrent Phase B * 10
145
U
3 / 4 OutputCurrent Phase C * 10
146
U
3 / 4 xid3017 Bits 0-15
147
U
3 / 4 xid3017 Bits 16-31
148
U
3 / 4 xid645 Bits 0-15
Powerfail Counter
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active; 0 = not active
1 = active (high)
0 = not active (low)
1 = active (high)
0 = not active (low)
1 = active (high)
0 = not active (low)
1 = active (high)
0 = not active (low)
Analog value
1 = closed
Outputvoltage Phase 1
Outputvoltage Phase 2
Outputvoltage Phase 3
Output Current Phase 1 in
Ampere *10
Output Current Phase 1 in
Ampere *10
Output Current Phase 1 in
Ampere *10
Statusbit of UPS 1 = true, 0 =
false
Statusbit, for details please
contact NEWAVE
Alarmbit, for details please
contact NEWAVE
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
71