Herunterladen Inhalt Inhalt Diese Seite drucken

Connect The Cable To The Indoor Unit - Zibro S1226 Installationshandbuch

Vorschau ausblenden Andere Handbücher für S1226:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.
All wiring must comply with local and national electrical standards and codes and be installed by qua-
lified and skilled electricians.
7.
An individual branch circuit and single receptacle used only for this air conditioner must be available.
See the following table for suggested wire sizes and fuse specifications:
Model
Power supply
<
3.5 kW
3.5 kW
model
220-240V~50Hz
< 6.1 kW
6.1 kW model
NOTE!
The supply voltage should be consistent with the rated voltage
of the air conditioner.

Connect the cable to the indoor unit

1.
Indoor/Outdoor connection cable should be H07RN-F type.
2.
Remove the panel and Screw, then remove the window cover.
3.
Connect cables according to their marks to terminals.
4.
Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any
electrical components.
5.
Fit the power cord clamp.
Panel
Window cover
ATTENTION
Always make sure that the electrical connection cables from indoor to outdoor unit are correct fitted,
e.g. when a green electrical line is fitted to clamp with code "L" in the indoor unit the other end of
that same green electrical line should be connected to clamp with code "L" on the outdoor unit.
Input Rated Current
Power Cord Size
(Switch/Fuse)
16A
1.0/1.5mm
16A
32A / 25A
Code wire
Terminal block of indoor unit
Cord clamp
2
1.5mm
2
2.5mm
2
Or
Or
To outdoor unit
To outdoor unit
Cord clamp
4
61

Werbung