3. INSTALLATION OF TEMPERATURE SENSORS

Handle the temperature sensors carefully! Remove wire bridges in
case of using 4-wire temperature sensors. The sensor cables are
usually fitted with coloured type labels.
Meter type
Heat meter in return
line
Heat meter in
forward line
Cooling meter in
return line
Cooling meter in
forward line
Air conditioning
meter in return line
Air conditioning me-
ter in forward line
Red: sensor in hot line, Blue: sensor in cold line.
The programmed installation location is documented in info-loop.
The free temperature sensor can be installed in a ball valve or in a
pocket. When pockets used these must be examined for confor-
mity for this sensor.
If the sensor is installed in a pocket, it must be inserted as far
as the bottom of the pocket and secured. A coupling set with
5-piece in separate bag is enclosed for installation in a ball valve.
Make sure the sensor is mounted symmetrically. A shorten or
extension of the sensor cable is not permissible. The cable length
is limited by 10m. It is preferred to install the sensor immersed
directly.
Sensor
2-wire
marking
Terminal
Red
5 TH 6
Blue
7 TC 8
Red
5 TH 6
Blue
7 TC 8
Blue
7 TC 8
Red
5 TH 6
Blue
7 TC 8
Red
5 TH 6
Red
5 TH 6
Blue
7 TC 8
Red
5 TH 6
Blue
7 TC 8
4-wire Ter-
Installation position
minal
1/5 TH 6/2
high temperature
3/7 TC 8/4
low temperature
1/5 TH 6/2
high temperature
3/7 TC 8/4
low temperature
3/7 TC 8/4
high temperature
1/5 TH 6/2
low temperature
3/7 TC 8/4
high temperature
1/5 TH 6/2
low temperature
1/5 TH 6/2
high temperature
3/7 TC 8/4
low temperature
1/5 TH 6/2
high temperature
3/7 TC 8/4
low temperature