The sensors – switching point and servicing
The switching point of the operating sensor (1) is in
about the middle of the pointed cone.
The switching point of the safety sensor (2) is about
11 mm (.43 in.) below the upper edge. Please make
sure that the black ring (3) always points upwards.
When using both sensors on the Magnet Holder
3155.600 (4), the space between the switching
points of the sensors is 25 mm (.98 in.) +/- 10 pc.
For the reliability of the sensor, the following points
have to be observed:
Always place the operating sensor in upright position
with the tip pointing down and the cable pointing up;
it is in this way only that it operates precisely.
Les capteurs, points de
fonctionnement et entretien
Le point de commutation du capteur de régulation (1)
se situe env. au milieu du cône.
Le point de commutation du capteur de sécurité (2)
se situe env. à 11mm de son bord supérieur. Veillez
à ce que l'anneau noir (3) soit toujours positionné
vers le haut.
Lors d'une utilisation des deux capteurs sur Magnet
Holder 3155.600 (4), la différence entre les points de
commutation des capteurs est de 25mm +/- 10%.
Pour une bonne fiabilité des capteurs, les points
suivants sont à observer :
Le capteur de régulation doit toujours être positionné
verticalement, pointe vers le bas et câble vers le
haut.