To ensure proper protection of terminals against hand contact, make sure that the live conductors are
properly connected to the terminals.
Do not establish any connections with non-allocated ("NC") terminals.
Counters may only be operated in a properly installed condition.
If safe operation seems to be impaired, make the counter inoperable and secure it against inadvertent
operation.
The installation and wiring environment has considerable impact on the electromagnetic compatibility of the
counter. Therefore, electromagnetic compatibility of the entire plant has to be ensured during the installation.
The fabricator of these complete units or systems takes responsibility for conforming to theCE Directive.
In areas presenting the risk of ESD (electrostatic discharge), make sure to use ESD-protected plugs and
switches during the installation.
If the functions "prescaler input", "preset input", "correction value" and "key reset" are not allowed to be used
by the machine/plant operator, access to these functions must be blocked for machine operators. Depending
on the machine/plant design or concept, non-permissible input may impair the operational safety and
function of the machine or plant.
In oily environments a delamination of the front sheet is possible. Therewith the tightness of the counter may
be affected. We suggest to use a protection cover as a countermeasure (see chapter 7, 9 and 14).