Herunterladen Diese Seite drucken

Specifications - WIKA S-10 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für S-10:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Specifications

)
Pressure ranges *
bar
Over pressure safety
bar
Burst pressure
bar
)
Pressure ranges *
bar
Over pressure safety
bar
Burst pressure
bar
{Vacuum, gauge pressure, compound range, absolute pressure are available}
1)
Only Model S-10.
2)
For model S-11: the value specified in the table applies only when sealing is realised
with the sealing ring underneath the hex. Otherwise max. 1500 bar applies.
Materials
Wetted parts
Model S-10
Model S-11
Case
4)
Internal transmission fluid
3)
O-ring made of FPM/FKM
4)
Not for S-10 with pressure ranges > 25 bar
Power supply U
U
in DC V
B
B
Signal output and
R
in Ohm
A
maximum load R
A
Adjustability zero/span
%
Response time (10 ... 90 %)
ms
Dielectric strength
DC V
5)
Use NEC Class 02 power supply (low voltage and low current max. 100 VA
even in fault conditions)
Model S-10 / S-11
0.1
0.16 0.25 0.4
0.6
1
1.6
2.5
1
1.5
2
2
4
5
10
10
2
2
2.4
2.4
4.8
6
12
12
16
25
40
60
100 160
250
400
80
50
80
120 200 320
500
800
96
96
400 550 800 1000 1200 1700
(other materials see WIKA diaphragm seal program)
Stainless steel
Stainless steel {Hastelloy C4}
3)
O-ring: NBR
{FPM/FKM or EPDM}
Stainless steel
Synthetic oil {Halocarbon oil for oxygen applications}
{Listed by FDA for Food & Beverage}
{
}
EPDM
for Model S-11 with integrated cooling element.
10 < U
≤ 30 (14 ... 30 with signal output 0 ... 10 V)
B
≤ (U
4 ... 20 mA, 2-wire R
- 10 V) / 0.02 A
A
B
≤ (U
0 ... 20 mA, 3-wire R
- 3 V) / 0.02 A
A
B
{0 ... 5 V, 3-wire}
R
> 5000
A
{0 ... 10 V, 3-wire}
R
> 10000 {other signal output on request}
A
± 10 via potentiometers inside the instrument
≤ 1 (≤ 10 ms at medium temperatures below -30 °C for
pressure ranges up to 25 bar or with flush diaphragm)
5)
500
Specifications
4
6
10
Accuracy
17
35
35
20.5 42
42
1)
600
1000
1200
1500
2)
2)
2400
3000
Non-linearity
1-year stability
Permissible temperature of
8)
)
Medium
*
8)
Ambience
8)
Storage
Compensated temp range
Temperature coefficients within
compensated temp range
Mean TC of zero
Mean TC of range
a- conformitiy
Shock resistance
Vibration resistance
Wiring protection
Model S-10 / S-11
≤ 0.25 {0.125}
6)
% of span
(BFSL)
≤ 0.5 {0.25}
6) 7)
% of span
6)
{ }
Accuracy
for pressure ranges > 0.25 bar
7)
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error
(corresponds to error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
≤ 0.2
% of span
(BFSL) according to IEC 61298-2
≤ 0.2
% of span
(at reference conditions)
-30 ... +100 °C {-40 ... +125 °C}
-22 ... +212 °F {-40 ... +257 °F}
S-11, cooling element: -20 ... +150 °C S-11, cooling element: -4 ... +302 °F
-20 ... +80 °C
-4 ... +176 °F
S-11, cooling element: -20 ... +80 °C
S-11, cooling element: -4 ... +176 °F
-40 ... +100 °C
-40 ... +212 °F
S-11, cooling element: -20... +100 °C
S-11, cooling element: -4 ... +212°F
8)
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
Transport (E) 2K3
0 ... +80 °C
32 ... +176 °F
≤ 0.2 / 10 K (< 0.4 for pressure range < 250 mbar)
% of span
≤ 0.2 / 10 K
% of span
89/336/EEC interference emission and immunity see EN 61 326,
interference emission limit class A and B
97/23/EG Pressure equipment directive (Module H)
g
1000 according to IEC 60068-2-27 (mechanical shock)
g
20 according to IEC 60068-2-6
Protected against reverse polarity and short circuiting
on the instrument side
(vibration under resonance)

Werbung

loading

Diese Anleitung auch für:

S-11