Herunterladen Diese Seite drucken

Temperature Sensor; Storage And Transport; General; Fork Lift (Or Lift Truck) Transport - Dimplex Lwp 200E Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für LWP 200E:
Verfügbare Sprachen

Verfügbare Sprachen

2.4 Temperature sensor

2.4.1 Temperature sensor
installation position
R1
R1
Air intake temperature sensor (integrated)
R3
Cylinder temperature sensor
Heat pump operation (integrated) positioned approx. 550
mm deep in the
immersion pipe of the cylinder.
2.4.2 Measured values temperature
sensor
Measured values NTC 10 sensor (R1, R3)
-20
-15
Temperature in °C
NTC-10 in k
67,7
53,4
15
20
25
30
35
14,9
12,1
10,0
8,4
7,0
www.dimplex.de
R3
-10
-5
0
5
10
42,3
33,9
27,3
22,1
18,0
40
45
50
55
60
5,9
5,0
4,2
3,6
3,1
451903.66.17 · FD 9303
3

Storage and transport

3.1 General

The domestic hot water heat pump should always be stored and
transported packaged in an upright position, without being filled
with water. If handled carefully, the device can be transported
over short distances with a maximum tilt angle of 45°. Ambient
temperatures between -20 and +60 °C are permissible during
transport and storage.

3.2 Fork lift (or lift truck) transport

The domestic hot water heat pump must remain mounted on the
pallet when being transported with a fork lift. The pump should be
lifted slowly. Because of its high centre of mass, the domestic hot
water heat pump must be secured against toppling. To prevent
damage, the domestic hot water heat pump must be lowered
onto a level surface.

3.3 Manual transport

The wooden pallet can be used underneath the device for the
purpose of manual transportation. A second or third carrying po-
sition can be created with the help of ropes or carrying slings
(these may be wrapped around the hot water cylinder casing and
attached to the water pipe nipples). If the pump is transported in
this manner (or with a hand truck), do not, under any circum-
stances, exceed the maximum tilt angle of 45° (see illustration).
ATTENTION!
The device cover cannot be used for carrying (the cover cannot withstand
significant forces).
LWP 200E
EN-5
loading

Diese Anleitung auch für:

451903.66.17