Herunterladen Inhalt Inhalt Diese Seite drucken

Problem Cart; Cleaning And Maintenance - Omnitronic DR-1000 MK2 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. PROBLEM CART

PROBLEM
No power.
No sound; receiver RF
indication does not light.
No
receiver
sound;
receiver
RF
indication
lights.
Received signal is noisy
or contains extraneous
sounds with transmitter
on.
Noise from receiver with
transmitter off.
Momentary loss of sound
as receiver is moved
around performing area.

8. CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
• Check connection cable of power unit and any extension cables.
• Make sure transmitter and receiver are switched on.
• Check receiver battery indication to ensure that batteries are providing power.
Replace batteries if necessary.
• Make sure that receiver is in line of sight of transmitter. If necessary, reduce
distance between transmitter and receiver.
• Turn up the level on transmitter.
• Check for proper connection between transmitter and mixer/amplifier.
• Apply signal to transmitter and observe receiver's RF indication. If it lights up
the problem is elsewhere in sound system.
• Adjust transmitter and receiver to same frequency.
• Check transmitter's battery indication to ensure that battery is providing power.
• Remove local sources of HF interference, such as lighting equipment.
• Two transmitters may be operating on the same frequency. Locate and turn
one off.
• Signal may be too weak. If possible, move receiver closer to transmitter.
• Remove local sources of HF interference, such as lighting equipment.
• Reposition the receiver.
• Reposition transmitter and perform another test and observe RF indication. If
audio drop-outs persist, mark dead spots in performing area and avoid them
during performance.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!