Herunterladen Inhalt Inhalt Diese Seite drucken

WimTec SanTec COOK Bedienungsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für SanTec COOK:
Inhaltsverzeichnis

Werbung

GB
Selection of programs
ATTENTION!
Adjustment of flushing programs only
possible in the first 10 sec. after initiation
(as soon as battery is inserted)
Program 1 factory-made pre-adjusted.
For changing the flushing program of an alrea-
dy adjusted control, the power supply must be
disconnected for at least 60 sec., afterwards a new
programming is possible.
Establish a close range reflex by hand
(hold hand 2 cm in front of the sensor window)
Red LED blinks:
Once = Prog. 1 - without proximity
*
reflex continuous flow resp. deactivation
manual with continuous flow
Twice = Prog. 2 - Continuous flow
**
Third = Prog. 3 - Cleaning stop
***
Fourth = Prog. 4 - Continuous flow and
****
cleaning stop
*****
Fifth = Prog. 5 - Continuous flow for
thermal disinfection, hygiene flush 3h
******
Sixth = Prog. 6 - Continuous flow for
thermal disinfection, hygiene flush 24h
Remove hand at the desired program (LED blinks
x times) - the control confirms the program by
blinking twice quickly.
Afterwards there are further 10 sec. for changing
the flushing program again. After lapse of this time,
the device blinks 3 times quickly and it changes into
normal function.
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis