FUSE CHECK/REPLACEMENT
1.
Disconnect the battery connector (8).
2.
Move aside the recovery water drain hose (11).
3.
Remove the battery charger cable from the cable holder (5).
4.
Remove the screws (A, Fig. 10) and carefully move aside the panel (B) by disengaging the grommet (C) from its housing on
the panel (B).
5.
Check/replace the following fuses:
• (D) Brush deck motor fuse F1 (40 A)
• (E) Vacuum system fuse F2 (30 A)
• (F) Electronic board fuse F3 (5 A)
6.
Perform steps 1 to 4 in the reverse order.
4/14
A
B
A
C
INSTRUCTION FOR USE
A
E
F
D
Figure 10
9100000444 - SCRUBTEC 453
ENGLISH
P100670
23