Herunterladen Inhalt Inhalt Diese Seite drucken

Fuse Check/Replacement - Nilfisk-ALTO SCRUBTEC 343.2 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

FUSE CHECK/REPLACEMENT

1.
Disconnect the battery connector (29).
2.
Remove the screws (A, Fig. 10), then carefully remove the electrical component box cover (B).
3.
Check the following fuses for integrity:
(C): F1 (40 A) circuit breaker, brush motor
(D): F2 (30 A) blade fuse, vacuum system motor.
(E): F3 (5 A) blade fuse, solenoid valve and electronic board
(E): F4 (20 A) glass fuse, brush disengagement system
4.
Replace the fuse, when the component that caused deactivation has fully cooled down.
Battery fuse (F0) (125 A) check/replacement
1.
Disconnect the battery connector (29).
2.
Remove the recovery tank (30) (see the procedure in Use chapter).
3.
Check or replace the battery fuse F0 (125 A) (B) on the battery connection cable (A, Fig. 11).
A
B
A
Figure 10
Figure 11
USER MANUAL
A
B
9099636000 - SCRUBTEC 343.2
ENGLISH
F
C
E
D
P100647
P100655
23