Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Control Elements; Tests And Approvals - Protool VCP700 E-LVCP700 E-M Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Technical data

Voltage
Mains frequency
Fuse
Power consumption
Connected load for appliance socket
Total connected load
Volume flow (air)
Negative pressure
Measurement area sound pressure level
at a distance of 1 m, EN 60704-1
Operating noise
Power cord: Length
Type
Protection class
Type of protection (splash water protected)
Radio interference level
Tank volume
Width × Depth × Height
Weight
Suction hose
Minimum air flow
diameter
volume
27 mm
690 l/min
32 mm
970 l/min
36 mm
1220 l/min
50 mm
2360 l/min
Accessories
Description
Filter bag (5 pcs.)
Waste bag (5 pcs.)
Filter element

Control elements

1. Handle
2. Extension hose holder
3. Accessories holder
4. Switch regulating suction power
5. Fastening catch
6. Waste container
8. Input fitting
9. Power point
10. Cable holder
12. Container stopper
13. Wheel with brake
14. Hose diameter setting (VCP 700 E-M)
VCP 700 E-L
230 V – 240 V
50/60 Hz
EU – 16 A
CH/DK – 10 A
AUS – 10 A
1200 W
EU – 2400 W
CH/DK – 1100 W
AUS – 1200 W
EU – 3600 W
CH/DK – 2300 W
AUS – 2400 W
3600 l/min
23 000 Pa
60 dB (A)
57 dB (A)
7.5 m
EU – H05 RR-F 3G1,5
CH/DK – H05 RR-F 3G1,0
AUS – H05 RR-F 3G1,5
I
IP X4
EN 55014-1
70 l
580 × 605 × 970 mm
27 kg
Associated negative pressure
between suction hose/tool
VCP 700 E-L
Order No.
632 735
632 737
626 437

Tests and approvals

The vacuum cleaners have been tested as specified
in IEC/EN 60335-2-69 including appendix AA. All the
requirements were fulfilled for equipment in dust
class (L/M).
The vacuum cleaners must be inspected regularly in
accordance with national accident prevention regu-
lations.
A dust test must be performed at least once every
year by the manufacturer or a trained person. This
test covers, for example, whether there is damage
to the filter, the vacuum cleaner is sealed to the air
and the control equipment works properly.
GB
VCP 700 E-M
230 V
50/60 Hz
16 A
1200 W
2400 W
3600 W
3600 l/min
23 000 Pa
60 dB (A)
57 dB (A)
7.5 m
H05 RR-F 3G1,5
I
IP X4
EN 55014-1
70 l
580 × 605 × 970 mm
27 kg
16 300 Pa
15 700 Pa
14 200 Pa
7800 Pa
VCP 700 E-M
Order No.
632 735
632 737
626 437

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis