It is not permissible to install the device vertically or on
the ceiling.
The protection areas defined in the current wiring regu-
lations must be observed during installation.
The supply connection socket must be accessible after
installation.
Installation on wooden walls is permissible.
Due to the heat radiation of the device, the surface on
which the device is installed can darken in colour.
Remove transport fastening
Loosen the front grill screws (A) and remove the
front grill.
Remove the transport fastenings (B) from the heat-
ing elements.
Re-attach the front grill.
B
B
A
Wall Mounting
To achieve the stipulated minimum installation height
of 1.8 metres, the mounting holes for the wall holder
must be drilled at a height of 1.9 metres.
Loosen the screw on the connection compartment
cover and remove the cover.
Fold the radiator forward.
Mark and drill the mounting holes on a vertical wall
and insert dowels.
Insert spacers with screws into the openings of the
wall holder and screw the device into place.
1. Electrical Connection
Heating device must be earthed!
Connect to permanently installed wiring only.
Cable must not be laid in the radiation area of the heat-
ing device and must not be in contact with the device's
casing.
EN-6
The voltage specified on the type plate must match the
mains voltage. It is recommended that a separate cir-
cuit be provided for the power supply. A separator with
a minimum contact opening of 3mm must be provided
on each pole in the permanently connected electrical
installation (e.g. a circuit breaker).
ATTENTION!
Only
heat
sheathed flexible cord should be used, the following
codes apply: IEC - 60227 IEC57 or CENELEC -
H05V2V2-F.
2. Operation
Do not use the device as a
changing table heater!
The radiator heats the objects
or persons upon which/whom
it is directed without also di-
rectly heating the indoor air.
The radiator can be tilted
downwards by a maximum of
40°.
A
Caution!
only be made when the device
is fully cooled. Danger of
burns!
The desired heating level can
be set by pulling the cord
switch once or repeatedly.
The set heating level can be
read in the display window.
In position 0, the heating device is switched off.
W = output power in watts.
Type
BK 1201
BK 2001
BS 1201
BS 1801
3. Faults
If the heating device does not give off heat, check the
following points:
Is the display at "0"?
Is the fuse in the fuse box switched on?
If the fault cannot be corrected, please contact your
electrical retailer.
If necessary, you can also call the Glen Dimplex
Deutschland service hotline.
Tel.: +49 (0) 9221 709-564
Fax: +49 (0) 9221 709-589
bk-bs-gb-ba · 05/15/D
resistant
ordinary
polyvinyl
Adjustments
may
Display 0
Display 1
Display 2
Off
1200 W
Off
800 W
1200 W
Off
600 W
1200 W
Off
600 W
1200 W
www.dimplex.de/en
chloride
Display 3
2000 W
1800 W