Herunterladen Inhalt Inhalt Diese Seite drucken

Fimer QUEEN 212EVO Bedienungsanleitung Seite 46

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ERRORE NR DESCRIPTION
E 9005
Low pressure water
Report appearing when water cooling
*
liquid pressure is inadequate due to li-
quid missing and air bubbles or ob-
structions inside of cooling circuit
E 9006
AC group overheating
Report appearing when the hardware
**
heat protection of polarity inversion group
sets in
E 9007
Inverter group overheating
or supply voltage out of allowed limits
or soft-start relé disconnected
Pressed torch button
E 9010
Release torch button and/or verify its
operation. Report appearing when the
torch button is pressed at machine's
ignition.
ERRORE NR
DESCRIPTION
W4700
Report appearing when inching wire button is pressed
W4701
SOLUTION
Check liquid level, make air bubbles bleed and check if
the circuit is open
Wait for machine's cooling
Check supply tension, if it's correct wait for the error to be
restored.
If the error remains for more than 10min. please contact
service assistance
Check if the torch button has been unaware pressed
and/or wrong operating
W4700. Manual wire loading
PROC.
PROC.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Queen 226evo

Inhaltsverzeichnis