Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha ql5 Referenzhandbuch Seite 307

Digital mixing console
Vorschau ausblenden Andere Handbücher für ql5:
Inhaltsverzeichnis

Werbung

s
Dynamic Range.
Input
Output
RL
*1
*2
600 Ω
INPUT 1-32
OMNI OUT 1-16
*2
600 Ω
OMNI OUT 1-16
*1. QL1: INPUT 1-16
*2. QL1: OMNI OUT 1-8
*3. Dynamic Range are measured with A-weight filter.
s
Sampling Frequency
Parameter
Fs= 44.1 kHz
Fs= 45.9375 kHz (44.1 kHz +4.1667%)
Fs= 44.1441 kHz (44.1 kHz +0.1%)
Fs= 44.0559 kHz (44.1 kHz –0.1%)
Fs= 42.336 kHz (44.1 kHz –4.0%)
Frequency
Range
Fs= 48 kHz
External Clock
Fs= 50 kHz (48 kHz +4.1667%)
Fs= 48.048 kHz (48 kHz +0.1%)
Fs= 47.952 kHz (48 kHz –0.1%)
Fs= 46.080 kHz (48 kHz –4.0%)
DIGITAL IN Fs= 44.1 kHz
Jitter of PLL
DIGITAL IN Fs= 48 kHz
Word Clock : Int 44.1 kHz
Frequency
Word Clock : Int 48 kHz
Word Clock : Int 44.1 kHz
Internal Clock
Accuracy
Word Clock : Int 48 kHz
Word Clock : Int 44.1 kHz
Jitter
Word Clock : Int 48 kHz
Fs= 48 kHz
Conditions
Min.
Typ.
AD + DA, GAIN: –6dB
108
DA Converter
112
Conditions
Min.
Typ.
–200
44.1
48
–50
Max.
Unit
dB
dB
Max.
Unit
+200
ppm
10
ns
kHz
+50
ppm
4.429
ns
4.069
45
Data List

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ql1Ql5

Inhaltsverzeichnis