VR 3000/3300
wirefeeder
Supply voltage
Power consumption
Gearbox
Wirespool types
max. wirespool weight
Wirespool diameter
Wire diameter
Wirefeed speed
Protection
Dimensions lxbxh
Weight
FK 3000 R coo-
ling unit
Pump motor mains voltage
Primary current input
Cooling circuit power +20° C
Feed rate
Feed height
Pump pressure
Coolant content
Protection
Measurements l x b x h
Weight (without coolant)
VR 3000
42 V DC
164 W
24,5:1
all standardised spools
16 kg
35.27 lb.
300 mm
11.81 in.
0.8 - 1.6 mm
0 - 18 m/min
0 - 708.66 ipm.
IP 23
(mm)
620 x 290 x 420
(in.)
24.41 x 11.42 x 16.54
16 kg
35.27 lb.
FK 3000 R
230 V, 50/60 Hz
0.8 A
1200 W
80° F
4094 BTU/hr.
+40° C
700 W
104° F
2388.26
3.0 l/min
6.43 cfh.
25 m
82 ft.
3.5 bar
50.75 psi.
5.2 l
1.37 gal. (US)
IP 23
215 x 240 x 480 mm
8.46 x 9.45 x 18.90 in.
11 kg
24.25 lb.
40
VR 3300
42 V DC
164 W
24,5:1
16 kg
35.27 lb.
300 mm
11.81 in.
0.8 - 1.6 mm
0 - 18 m/min
0 - 708.66 ipm.
IP 23
600 x 260 x 440
23.62 x 10.24 x 17.32
13 kg
28.66 lb.