Herunterladen Inhalt Inhalt Diese Seite drucken

Maintaining And Cleaning The Device; Troubleshooting - Waeco PerfectCharge MCA1215 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Maintaining and cleaning the device

10
Maintaining and cleaning the device
A
NOTICE!
Do not use any sharp or hard objects for cleaning since they may
damage the device.
➤ Disconnect the device from the 230 V power supply.
➤ Disconnect the device from the battery.
➤ Prevent the device from being switched on.
➤ Occasionally clean the device with a damp cloth.
➤ Regularly clean the vents.
➤ Check the electrical wiring at least once a year.
Repair any defects such as loose connections or burnt cables.
11

Troubleshooting

The "Status" LED (fig. 1 5, page 3) displays the fault:
LED display
Red, slowly flashing
Red, slowly flashing
Red, permanently lit
Red, double flash
Red, slow double
flash
60
Cause
Battery undervoltage or bat-
tery overload
Defective battery
Overheating
Short circuit or reversed
polarity
Fan fault
Fault at the starter battery
connection
MCA1215 – MCA2440
Remedy
Check the battery.
Switch the battery charger off and on
again.
Replace the battery.
Improve the ventilation of the battery
charger or battery.
Make sure that no ventilation open-
ings are covered.
If necessary, reduce the ambient
temperature.
Connect the battery charger with the
correct polarity.
Rectify the short circuit.
Check if the fuse has triggered and
replace it if necessary.
Check the fan for dirt or damage.
Check the starter battery connection
for a short circuit.
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis