Errors are indicated by the following:
1. The alarm does not sound when pressing the test button.
* Carefully vacuum the smoke detector (see Cleaning), test
afterwards. Still no reaction; replace smoke detector
2. The detector "chirp" with red LED flashes once every 40 sec.
* The battery is under low battery status, please replace the
smoke alarm
3. Smoke alarm "chirp" occurs every 40 seconds
(alarm goes into fault mode)
* Clean smoke detector. Please refer to maintenance section.
When problem is not solved replace smoke alarm.
4. Smoke alarm sounds unwanted alarms intermittently or when
resident are cooking or taking showers.
* Press test button to pause alarm.
* Clean smoke alarm (maintenance section)
* Move smoke detector to other place and press test button
-11-
If these actions do not solve the problem, do not try to repair it
yourself. If the problems occur within the warranty period and are
under warranty conditions, return the smoke detector plus valid
proof of purchase with a clear description of the complaints to:
smartwares
safety & lighting b.v.
Broekakkerweg 15
5126 BD Gilze
The Netherlands
www.smartwares.eu
SPECIFICATIONS
Power
: 3V DC CR123A Lithium
(not replaceable battery)
Operating temperature : 4 ~ 38°C
Operating humidity
: 25 ~ 85%
Smoke sensor
: Optical
Alarm volume
: > 85db(a) at 3 meters.
Pause time
: approx. 10 minutes
: For indoor use only.