Herunterladen Inhalt Inhalt Diese Seite drucken

Grundig LENARO 92 MFW 92-6110/9 DVD Service Anleitung Seite 38

Inhaltsverzeichnis

Werbung

Abgleich / Alignment
Alignment
12. Picture
Feed in a convergence test pattern.
sharpness
On 16:9 units, set the picture format to 16:9.
(TV sets without
Contrast:
focus block)
Set the brightness so that the black test pattern background
just brightens.
Line sharpness
Feed in a convergence test pattern.
(TV sets with
On 16:9 units, set the picture format to 16:9.
focus board)
Contrast:
Set the brightness so that the black test pattern background
just brightens.
Line sharpness
Feed in a convergence test pattern.
(TV sets with
On 16:9 units, set the picture format to 16:9.
focus block)
Contrast:
Set the brightness so that the black test pattern background
just brightens.
13. Screen grid
Feed in a black raster.
voltage U
Adjust the picture screen brightness so the the grey area
SG
just darkens.
Switch the unit to AV mode.
High-impedance voltmeter:
Determine the test point with the highest voltage level.
14. Adjustment of
The bridge coil L53574 is adjusted during production and
the bridge coil
should not be re-adjusted any more.
L53574
Call up the "Screen geometry" menu via "EASY DIALOG" –>
"Installation" (to page 2) –> "Dealer service menu" –>
"8500".
Set the picture width to minimum.
Oscilloscope channel 1: collector T53501.
Oscilloscope channel 2: cathode D53572.
15. IF-Type
Call up the "IF-Type" menu via "EASY DIALOG" –>
"Installation" (to page 2 / option) –> "Dealer service menu" –>
"8500" –> "Hardware settings".
2 - 6
Preparations
Maximum.
Maximum.
Maximum.
Test point R, G, B
(picture tube plate).
Alignment procedure
Use the FOC control on the picture tube panel to adjust the
vertical lines about 5 cm to the right and left picture border
for minimum horizontal width.
Use the FOC control on the picture tube panel to adjust the
horizontal lines in the picture centre for minimum vertical
width. When this is done, use the focus control on the focus
board to adjust the vertical lines about 5 cm to the right and
left picture border for mimimum horizontal width.
Use the FOCUS 1 control on the focus block to adjust the
horizontal lines in the picture centre for minimum vertical
width. The upper border sharpness must not be worse than
the centre sharpness - set to average value if necessary.
When this is done, use the FOCUS 2 control on the focus
block to adjust the vertical lines about 5 cm to the right and
left picture border for minimum horizontal width.
Units without focus block:
Use the SG control (right control on the regulating section)
on the picture tube panel to adjust 170V
Units with focus block:
Use the "SCREEN" (bottom control on the focus block) to
±
adjust 170V
2.5V.
Check for equal impulse width of the oscillograms and
correct if necessary using the coil L53574.
Re-adjust the picture width according to the test pattern.
Ajust to IF Type built into the set.
National, Multi 8, Multi 9.
DIGI 100
±
2.5V.
GRUNDIG Service

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Digi 100 mit dvd/ac3

Inhaltsverzeichnis