Herunterladen Inhalt Inhalt Diese Seite drucken

Grundig LENARO 92 MFW 92-6110/9 DVD Service Anleitung Seite 36

Inhaltsverzeichnis

Werbung

Abgleich / Alignment
Alignment
GB
All adjustment controls not mentioned in this description are adjusted during production and must not be re-adjusted in the case of repairs.
Call up the service menu:
Call up the dialogue line:
Change setting in the dialogue line:
Back to previous menu:
Exit menu:
Service menu for the dealer (code no.): "8500"
Measuring instruments: 100MHz oscilloscope with 10:1 test probe, digital voltmeter, colour test pattern generator
Checks and adjustments after replacement or repair of:
- Chassis: alignment 1
- Signal module: alignment 2
-
CIC31010
(signal module): alignment 2, 15
- PIP/signal module: alignment 3, 4
-
CIC80230
(feature module): alignment 5...11
- Horizontal deflection: alignment 12, 13, (14)
Alignment
1. +A voltage
It is absolutely necessary to check and re-adjust these
voltages if necessary after every repair and before
every alignment.
Digital voltmeter: D61516 / cathode
Brightness:
2. Tuner AGC
Connect the 100MHz oscilloscope to the tuner contact 10
(signal module)
or 11 and to tuner ground.
Feed in a test pattern (sound carrier switched off) via the
aerial, 70...80dBµV.
Call up the "AGC setting" menu via "EASY DIALOG " –>
"Installation" (to page 2) –> "Dealer service menu" –>
"8500" –> "Special functions".
3. Tuner AGC/PIP
Connect the 100MHz oscilloscope to the tuner contact 10
(PIP/signal
or 11 and to tuner ground.
module)
Feed in a test pattern (with sound carrier switched off) via
the aerial, 70...80dBµV.
Display a PIP picture.
4. PLL demodu-
Feed in a transmitter signal with standard channel spacing,
lator circuit for
Band 1 (B/G).
38.9MHz
Tune the set to a transmitter with "00" finetuning.
picture carrier
Display a PIP picture.
(PIP/signal
Voltmeter:
module)
Voltmeter:
PLL demodu-
Feed in a transmitter signal with standard channel spacing,
lator circuit for
Band 1 (L`).
33.4MHz
Tune the set to a transmitter with "00" finetuning.
picture carrier
Display a PIP picture.
(PIP/signal
Voltmeter:
module)
Voltmeter:
5. Colour match
Call up the "Colour match" menu via "EASY DIALOG" –>
"Installation" –> "Special functions" (to page 2).
6. Channel position-
Call up the "Noise reduction" menu via "EASY DIALOG" –>
related noise
"Settings" –> "Picture" (to page 2) .
reduction
Programme
positions
Call up the "Noise reduction P. 1...199" menu via "EASY
1...199
DIALOG" –> "Installation" –> "Special functions".
2 - 4
Button " "
(EASY
DIALOG)
Buttons "P+" or "P-" –> "OK"
Buttons "L+" or "L-" –> "OK"
"blue" button
Button " "
Preparations
Minimum
IC32110-22.
IC32110-11.
IC32110-22.
IC32110-11.
Alignment procedure
Use the R61508 control to adjust the value according to the
table (page 3-19).
Set to 300-350mV
.
pp
Use the RV R32122 control to set 300-350mV
PIP/signal module.
Determine the exact operating voltage UB.
Set half the operating voltage UB/2 with F32085 on the
PIP/signal module (295042120400).
Determine the exact operating voltage UB.
Adjust half the operating voltage UB/2 with R32334 on
the PIP/signal module (295042120400).
Optimize existing run time differences between the Y and
chroma signals. The channel positions 1...199 are
optimized at the same time.
Set the noise reduction ("off", "low", "automatic", "high") for
every channel position.
Set the noise reduction ("manual", "off", "low", "automatic")
for the channel positions 1...199 at the same time.
DIGI 100
on the
pp
GRUNDIG Service

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Digi 100 mit dvd/ac3

Inhaltsverzeichnis