DIGI 100
2
1.8.1 I
C Bus, IC Test
In this fault finding programme, the CIC80050 processor scans the
individual modules or circuits connected to the I
them as countable flashing sequence on the LED of of keyboard
control unit.
Press and hold down "P+" on the remote control and switch the TV set
on with the mains button.
The number of flashing pulses indicates the defective module according
to the table.
Flashing sequence example:
red LED flashes quickly for 10s
yellow LED lights for 4s
green LED flashes (e.g. 2 times) = tens's place (2)
green LED lights for 4s
green LED flashes (e.g. 8 times) = units's place (8)
Result
With the "L+" button on the remote control is is possible to find out
further defective interfaces.
IC
Flashing
designation
frequency
CIC31010
1
CIC70200
2
CIC70250
3
CIC70300
4
CIC33010
5
IC43140
6
TUNER
7
CIC32040
8

2. Special Functions in the "Installation" Menu

2.1 Entry of Letters
Call up the "Letter entry" menu via "EASY DIALOG" –> "Installation"
–> "Special functions".
You may select between "off", "on" and "mix" for the programme
selection letter entry.
2.2 Visible or Unvisible "Sound scale" for all Programmes
Call up the "Sound scale" menu via "EASY DIALOG" –> "Installation"
–> "Special functions".
With "off" selected, no volume bar is displayed.
2.3 Switch on with Programme "1", or automatically
Call up the "Switch on " menu via "EASY DIALOG" –> "Installation" –>
"Special functions" .
Set the option "Programme position 1" or "automatic".
With the "automatc" setting, the programme position selected when
switching off is selected again when switching the set on again (Last
station memory).
2.4 "Megalogic info" (only if the Megalogic feature is identified)
Call up the "Megalogic info" menu via "EASY DIALOG" –>
"Installation" –> "Special functions".
The Megalogic´control can be switched to "on" or "off".
2.5 Status Display
Call up the "Status display" menu via "EASY DIALOG" –>
"Installation" –> "Special functions" .
You may select the position (top or bottom) where the information
about the sound mode and the picture format is displayed.
With the "off" option, no information is displayed when changing the
programme.
2.6 Automatic Volume
Call up the "Autom.volume" menu via "EASY DIALOG" –>
"Installation" –> "Special functions".
In the "ON" position, the sound IC regulates the volume internally to the
normal value ( e.g. increased deviation in the case of advertising).
GRUNDIG Service
2
C bus and indicates
= 28
Defective module/
integrated circuit
Signal Module
Feature Module
Feature Module
Feature Module
Signal Module
Signal Module
Signal Module
Signal Module
2.7 Noise Reduction P1...99 or P1...199 (with SAT module)
Call up the "Noise reduction P. 1...99" menu via "EASY DIALOG" –>
"Installation" –> "Special functions. For the programmes 1...99 or
1...199 you may set the noise reduction to "off", "low" or "automatic".
With the "manual" setting, the display indicates that one or several
programmes have different settings.
2.8 Picture Sharpness P1...99 or P1...199 (with SAT module)
Call up the "Sharpness" menu via "EASY DIALOG" –>
"Installation" –> "Special functions" (to page 2).
The picture sharpness is set for all programmes.
2.9 Colour Match
Call up the "Colour match" menu via "EASY DIALOG" –> "Installation"
–> "Special functions" (to page 2).
The colour match (luma delay) is set for every programme.
On sets with PIP module, the colour match for the PIP picture can be
set individually.
2.10 Rotation
Call up the "Rotation" menu via "EASY DIALOG" –> "Installation" –>
"Special functions".
Adjust the display angle of the picture with respect to the picture to zero.
N/S trapezium in Geometry menu.
3. Format Switching
3.1 Format Switching with Evaluation of the Switching Voltage
Depending on the voltage present on Pin 8 of the active EURO-AV
socket, the set adjusts the picture format. In AV mode, the picture
format switching is active for the AV socket (AV 1, AV 2, AV 3) .
With 16:9 picture tubes
Picture format be- New picture format after New picture format after
fore voltage change Pin 8: 0/12V –> 6V
16:9
-
Cinema Zoom
16:9
Panorama Zoom 16:9
4:3
16:9
With 4:3 picture tubes
Picture format be- New picture format after New picture format after
fore voltage change Pin 8: 0/12V –> 6V
16:9
-
4:3
16:9
Panorama Zoom
16:9
* old format means the format adjusted manually before the last voltage
change.
4. Service Settings for the Retailer
4.1 Picture Screen Geometry
Call up the "Screen geometry" menu via "EASY DIALOG" –>
"Installation" –> "Only for the retailer" –> "8500".
Align the geometry test pattern beginning with the vertical alignment
(see alignment point 11).
4.2 Picture Settings
4.2.1 White Balance
Call up the "White balance" menu via "EASY DIALOG" –> "Installation"
–> "Only for the retailer" –> "8500" –> "Picture settings".
Adjust the values for "red", "green" and "blue" so that a white picture
is obtained. (See Alignment, Point 8).
4.2.2 Switching the Blue Screen Background On and Off
Call up the "Blue screen" menu via "EASY DIALOG" –> "Installation"
–> "Only for the retailer" –> "8500" –> "Picture settings".
Select "on" or "off".
4.3 Hardware Settings
4.3.1 Picture Tube Type
Call up the "Tube type" menu via "EASY DIALOG" –>
"Installation" –>
"Only for the
retailer" –> Code number "8500" –>
"Hardware settings".
Select the appropriate picture tube type.
Allgemeiner Teil / General Section
Pin 8: 6V –> 0/12V
old format *
old format*
old format *
old format* *
Pin 8: 6V –> 0/12V
old format *
old format *
old format *
1 - 31

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Digi 100 mit dvd/ac3

Inhaltsverzeichnis