Fuse Replacement
Switch the device off.
Separate the device from the mains voltage disconnecting the mains plug from the mains socket.
• Remove the fuse holder of the back of the device turning it counterclockwise with a suitable screwdriver.
• Remove the defective fuse and replace it by a new fuse of the same type (type / nominal current / nominal
voltage / triggering characteristics). Fine-wire fuse 5 * 20 mm, 1A, 250VAC, surge-proof.
• Put the fuse holder back into the device turning it clockwise. Make sure that the fuse holder fits in the
device correctly.
Transport
Do not transport the device with liquid filled in. Switch the device off. Disconnect the mains plug from the
mains socket. Open the device (see "Operation") and empty the liquid. Dry the container. Then, close the
device (see "Operation"). Secure the device cover with the recessed head screws before transport screwing
them into the device next to the knurled screws. Use the original packaging material for transport in order to
avoid damages caused by transport.
Disposal
Dispose of the unserviceable device according to the relevant statutory requirements.
Maintenance and Care
Please observe the safety instructions before cleaning the device. Clean the product with a moistened cloth
or a brush. Never use aggressive cleansing agents or chemical solutions because these might damage the
product.
Technical Data
Power supply:
230 VAC / 50 Hz via shockproof socket
Power consumption:
approx. 25 W
Fuse:
1 A / 250 VAC, surge-proof, 5 * 20 mm
Safety class:
I, IP20
Container content:
ca. 400 ml
Dimensions (w x h x d):
170 mm x 185 mm x 330 mm
Weight without liquid:
approx. 4.2 kg
10
Introduction
Dear customer,
We thank you for acquiring this Soap Bubble Machine.
With this product you acquired a state-of-the-art device.
This product corresponds to the standards of the established European and national guidelines. CE-con-
formity has been proven; the relevant documents are in the manufacturer's possession.
To preserve this condition and to ensure safe operation, the user has to heed this operating manual!
In case of questions, consult our technical information service
Germany: Tel. 0180/5 31 21 18 or 09604/40 88 46
Fax 09604/40 88 44
e-mail: tkb@conrad.de
Mon - Fri 8.00 to 18.00
Austria: Tel. 0 72 42/20 30 60 · Fax 0 72 42/20 30 66
e-mail: support@conrad.at
Mon - Thu 8.00 to 17.00
Fri. 8.00 to 14.00
Switzerland: Tel. 0848/80 12 88 · Fax 0848/80 12 89
e-mail: support@conrad.ch
Mon - Fri 8.00 to 12.00, 13.00 to 17.00
Prescribed Use
This product is intended to produce soap bubbles. It can be used for theatre purposes and on stage as well
as for discos, clubs, parties etc.
Only operate the device indoors and in dry rooms. The product is not splash-proof and therefore not admis-
sible for outdoor use. Furthermore, the device is not admissible for industrial use.
Only use special Soap Bubble concentrate thinned with water and approved for this purpose. (Con-
rad item no. 59 00 13 normal, item no. 59 00 19 UV-active).
Only connect this product to a mains socket of the public mains (230V / 50 Hz (10/16A) alternating voltage
AC) with protective conductor.
Any use different to the one described above damages the product. Moreover, this involves dangers, such
as e.g. short-circuit, burning, electric shock etc.