b) Fuse
• Only fit or replace a fuse when the device is unplugged from the mains.
• Replace a blown fuse with a fuse of the same type and rating (see "Technical Specifications"):
1. Unplug the device from the mains.
2. Unscrew the fuse holder at the back with an appropriate screwdriver.
3. Remove the old fuse and install a new one.
4. Replace the fuse holder and fasten it with the screwdriver.
c) Mounting the Device
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
• The construction to which the device is attached should be able to support 10 times the weight of the device for
one hour without deformation.
• The installation must always be secured with a secondary attachment e.g. a safety cable.
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician
check the device once a year and once before you bring it into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience: calculating workload limits, determining the installation
material to be used... Have the material and the device itself checked regularly. Do not attempt to install the
device yourself if you lack these qualifications as improper installation may result in injuries.
• Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
• Make sure there is no flammable material within a 50cm radius of the device.
• Have a qualified electrician carry out the electric connection.
• Connect the device to the mains with the power plug. Don't connect it to a dimming pack.
• The installation has to be approved by an expert before the device is taken into service.
5. Use
Insert the plug of the remote control in the socket on the back of the device. Connect the device to the mains. The
warm-up lamp lights up. After the warm-up time (approx. 4 to 5 minutes) the device is ready for use. The warm-up
lamp on the remote control will be off. Flick the switch on the remote control to start the smoke emission or to stop
the emission. It may happen that the warm-up lamp on the remote control lights up and the smoke emission stops,
even though the switch is set to 'I'. It means the device is warming up again and will be ready in approx. 2 minutes.
This process guarantees an appropriate vaporization temperature and the best smoke emission possible.

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections, ...
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts, apart from the fuse (see "Installation").
8. Contact your dealer for spare parts if necessary.
9. Clean the heating element every 30 hours of use with a special cleaning liquid available from your dealer. Fill the
tank with the cleaning liquid and let the machine run for a while. When the device is cleaned, remove the
remaining cleaning liquid and rinse the tank thoroughly with distilled water. Never use regular water for cleaning
or rinsing!