6.4

Wireless Remote Control

The included wireless remote control (Velleman
to 4 devices. Assign each device to one push button of the wireless remote control. Each
device will output fog/smoke for as long as the respective button is being pressed.
7.
Troubleshooting
No or erratic fog/smoke
output.
Fuse keeps blowing.
Device does not power up.
Loud noise.
If you still experience problems, please contact your nearest Velleman
8.

Cleaning and Maintenance

Before starting any cleaning or maintenance activities:
1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
Cleaning
Use normal glass cleaner and a soft cloth to wipe off the outside casing.
Always be sure to dry all parts completely before plugging the device back in.
Cleaning frequency depends on the environment in which the unit operates (i.e.
smoke, fog residue, dust, dew).
Do not immerse the device in any liquid.
Maintenance
All screws should be tightened and free of corrosion.
The housing, the lenses, the mounting supports and the installation location (e.g.
ceiling, suspension, trussing) should not be deformed, modified or tampered with;
e.g. do not drill extra holes in mounting supports, do not change the location of the
connections...
Mechanically moving parts must not show any signs of wear and tear.
V. 03 – 02/09/2020
symptom
HQSM10007
®
order code HQRC10001) can control up
possible cause
Incorrect liquid.
Blocked pipe or failing part.
Incorrect power connection
or failing fuse.
Low or no liquid.
Excessive load on the
circuit.
Short-circuit along mains
power.
Damaged power cord.
Blown fuse.
Internal problem.
Low or no liquid.
Damaged pump system.
7
possible solution
Drain the liquid, clean
thoroughly and use the
correct liquid.
Contact your nearest
dealer.
Check the power
connection and fuse.
Refill the tank with liquid.
Make sure that the total
load does not exceed 80 %
of the fuse nominal
current.
Check the mains power
and power cord.
Check the power cord.
Replace the blown fuse
with a new one of the
same type and rating.
Contact your nearest
dealer.
Refill the tank with liquid.
Contact your nearest
dealer.
®
dealer.
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis