TECHNICAL DATA:
MEASUREMENTS W x H x D:
WEIGHT:
RATED OUTPUT:
FLUE OUTLET:
FUEL:
DESCRIPTION, INSTALLATION AND OPERATING INSTRUCTIONS
We are pleased to deliver this fireplace
Please read carefully these Installation and Operating Instructions prior to proceeding with regular
use.
INSTRUCTIONS FOR USE
When installing the fireplace, make sure that relevant local, national and European regulations are fully
complied with. The installation shall be made in accordance with applicable civil engineering regulations.
Our liability shall be strictly limited to the delivery of this product in good operating conditions. Therefore,
after having unpacked the product, inspect it carefully for possible damages in transport. Any such damages
should be immediately reported, because late claims will not be taken into consideration.
The fireplace shall be installed in accordance with these Instructions and building trade rules and by
qualified staff that shall be responsible for proper installation of the product.
Vesta Insert is composed of a sheet metal shell enclosing a cast iron firebox with baseplate and cap also
made of cast iron. Joints between individual component parts are sealed with fire resistant coat and
screwed together. The door and the glass are sealed with fibreglass material, granting adequate sealing of
the appliance as a whole.
In the lower part, there is an ash tray and primary air supply control. Above the door glazing openings are
provided for the supply of secondary air which supports the combustion and prevents the glass staining.
Space heating is achieved by:
- convection of the air flowing between the enclosed portion of the fireplace and the
masonry fireplace wall through supply and exhaust grids
- heat radiation from the faceplate and glazed door
The appliance shall be positioned on a level surface, in a room with sufficient fresh air supply to support
combustion. Regular fresh air supply should be provided through a separate opening near the fireplace,
protected with a non-clogging grid. This is particularly important if an exhauster (hood) or similar air-
consuming unit is installed in the same room.
Output selection depends on the building insulation grade, weather conditions, exposure of the building, in
particular exposure to wind, etc.
For connection to the chimney, the use of a common (standard) flue pipe is recommended (inner dia
Ø150mm).
Make sure that the connections of the flue pipe with the flue outlet and with the chimney outlet are firm and
tight. The flue pipe shall not extend beyond the chimney lining i.e. shall not protrude into the cross section of
the chimney.
500x822x535 mm
100 kg
7 kW
Ø150 mm
Wood,
wood briquettes
Vesta Insert
20