19. Cleaning

Apart from occasional cleaning of the housing and ventilation openings, the product is maintenance free; do not
dismantle it.
Before cleaning the product, switch it off and disconnect it from the voltage source.
Do not use any aggressive cleaning agents or petrol, alcohol or the like to clean the product. They will damage the
surface of the device. Furthermore, the fumes are hazardous to your health and explosive. Also do not use any sharp-
edged tools, screwdrivers, metal brushes, etc. for cleaning.
Use a clean, lint-free and antistatic cleaning cloth for cleaning the device or the display.

20. Disposal

The product does not belong in the household waste.
Dispose of the product according to the statutory provisions at the end of its service life.

21. Technical Data

Input voltage .....................................................19 - 33 V/DC
Fixed output voltage .........................................13.8 V/DC with 0.5 A
Adjustable output voltage .................................12 - 15 V/DC (in 0.2 V-steps)
Output current ...................................................Maximum 40 A
Idle current consumption ..................................<50 mA
Protection function ............................................ Overvoltage, overload, temperature, in- or output with reversed polar-
Efficiency ..........................................................>90%
Battery charge function .....................................Quick charge (14.3 V)
..........................................................................Maintenance charge (13.6 V)
Rechargeable battery capacity .........................130 Ah to 400 Ah
External alarm output .......................................13.5 V/DC/0.25 A
LCD ..................................................................Voltage, current, error diagnosis, charge function
Cooling .............................................................Temperature-controlled fan
Working conditions ...........................................-10 °C to +50 °C (10% to 80% relative humidity)
Storage temperature .........................................-15 °C to +70 °C (10% to 85% relative humidity)
Weight ..............................................................Approx. 1200 g
Dimensions (L x W x H) ....................................190 x 130 x 55 mm