10. Two-level battery charge mode
When the device is in charging mode, the LED display (3) shows
The main charge [1] is performed with a maximum constant current of 40 A and a maximum voltage of 14.3 V. In
maintenance charge mode [2], the voltage is 13.6 V.
The charge symbol (1) flashes at quick charge and remains lit continually at maintenance charge. Pushing the SET
button (4) will display the charge voltage and the current. Please observe that
able battery is full and the maintenance charge current is less than 1 A.
11. Display
The output current is below 1A
Charge mode
Setting mode Setting the voltage and current
The remote control is deactivated. Once an input voltage is pending, an output voltage is output
Factory settings activated
Charge display flashes Charging
Charge display lit Maintenance charge
an and the charge symbol (1) is active.
is displayed when the recharge-
23