6. Operating Elements
1
Display charge mode
2
SET button for settings
3
LED display
4
Displays for current or voltage
5
Connection terminals
Input voltage 19 - 33 V/DC
6
Auxiliary contacts
7
Connection terminals
output voltage 12 - 15 V/DC
A
View from top
B
View from the front
C
View from the rear
a) Display
1
The rechargeable battery icon is active in charge mode
2
SET (setting) button
3
Display for voltage, current, function and error code
4
LED display for voltage (V) and current (A)
b) Auxiliary contacts
Remote
Connection for automatic/manual switching on/off
13.8V 0.5A
Continually active permanent voltage output at 13.8 V / 0.5 A
GND
Ground terminal
NC
Not connected
Alarm
Connection terminals for undervoltage alarm with 13.5 V/DC and 0.25 A
(for one LED or beeper)
S+ S-
Connection terminals for remote voltage measurement (plus/+ or minus/-)
20