INSTALLATION

Safety

INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1

General safety instructions

We can only guarantee trouble-free function and operational reli-
ability if original spare parts intended for the appliance are used.
6.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
7.

Appliance description

7.1

Standard delivery

The following are delivered with the appliance:
SB S
- Cylinder incl. thermal insulation (directly applied foam)
- Cylinder casing
- Thermometer (in the flange aperture)
- Adaptor with flat gasket for the connection of a DHW circula-
tion line
- Cold water inlet pipe with flat gasket
- Adhesive bezel
- Adjustable feet
SB 602 AC | SB 1002 AC
- Cylinder excluding thermal insulation
- Thermometer (in the flange aperture)
- Anode consumption indication
- Label "Signal anode information"
- Information leaflet "Pressure relief valve"
SB 650/3 AC
- Cylinder excluding thermal insulation
- Information leaflet "Pressure relief valve"
18
| SB S | SB AC
7.2

Accessories

Required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against impermissible excess pressure.
Further accessories
Dummy flanges, threaded immersion heaters, flanged immersion
heaters and internal indirect coils are available as accessories.
If it is not possible to fit an anode rod from above, install a seg-
mented signal anode.
SB AC:
The thermal insulation is available as accessory.
8.

Preparations

8.1

Installation site

Always install the appliance in a room free from the risk of frost
and near the draw-off point.
SB S
f Use the adjustable feet to compensate for any unevenness in
f
the floor.
SB AC
f Secure the appliance to the floor.
f
8.2

Transport

SB S
Material losses
!
We recommend removing the cylinder casing for trans-
portation to the installation location to prevent it from
becoming dirty or damaged (see chapter "Installation /
Preparing the DHW circulation line connection, if appli-
cable").