Herunterladen Diese Seite drucken

Allgemeiner Teil; General Section - Grundig VERTIGA UMS 4600 DEC Bedienungsanleitung

Werbung

GRUNDIG Service
Es gelten die Vorschriften und Sicherheitshin-
weise gemäß dem Service Manual "Sicherheit",
Materialnummer 720108000001, sowie zusätz-
lich die eventuell abweichenden, landes-
spezifischen Vorschriften!
Inhaltsverzeichnis

Allgemeiner Teil ............................... 1-2 ... 1-12

Messgeräte / Messmittel .............................................................. 1-2
Allgemeine Hinweise .................................................................... 1-2
Technische Daten ........................................................................ 1-3
Servicehinweise ........................................................................... 1-3
Bedienhinweise ............................................................................ 1-4
Ausbauhinweise ......................................................................... 1-12
Abgleichvorschriften .................................... 2-1
Platinenabbildungen
und Schaltpläne ............................... 3-1 ... 3-14
Blockschaltplan ............................................................................ 3-1
Verdrahtungsplan ......................................................................... 3-2
Netzteil ......................................................................................... 3-3
Verstärker .................................................................................... 3-4
Hauptplatte ................................................................................... 3-5
CD-Teil ......................................................................................... 3-8
USB-Teil ..................................................................................... 3-11
Display-Platte/Bedienteil ............................................................ 3-13
Explosionszeichnung und
Ersatzteilliste ...................................... 4-1 ... 4-2
Explosionszeichnung ................................................................... 4-1
Ersatzteilliste ................................................................................ 4-2
Allgemeiner Teil
Messgeräte / Messmittel
Mess-Sender
Oszilloskop
Trenntrafo
Allgemeine Hinweise
Vor dem Öffnen des Gehäuses zuerst den Netzstecker ziehen!
Achtung: ESD-Vorschriften beachten
Leitungsverlegung
Bevor Sie die Leitungen und insbesondere die Masseleitungen lösen,
muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet
werden.
Nach erfolgter Reparatur ist es notwendig, die Leitungsführung wieder
in den werkseitigen Zustand zu versetzen um evtl. spätere Ausfälle
oder Störungen zu vermeiden.
Durchführen von Messungen
Bei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nur
Tastköpfe mit 10:1 - Teiler verwenden. Außerdem ist zu beachten,
dass nach vorheriger Messung mit AC-Kopplung der Koppelkonden-
sator des Oszilloskops aufgeladen sein kann. Durch die Entladung
über das Messobjekt können Bauteile beschädigt werden.
Messwerte
Bei den in den Schaltplänen angegebenen Messwerten handelt es
sich um Näherungswerte!
Seite
Wobbelsender
Digitalvoltmeter
Klirrfaktormessgerät
The regulations and safety instructions shall be
valid as provided by the "Safety" Service Manual,
part number 720108000001, as well as the re-
spective national deviations!
Table of Contents

General Section ................................ 1-2 ... 1-12

Measuring Instruments / Equipment ............................................ 1-2
General Notes .............................................................................. 1-2
Technical Data ............................................................................. 1-3
Service Hints ................................................................................ 1-3
Operating Hints ............................................................................ 1-8
Disassembly Hints ..................................................................... 1-12
Adjustment Procedures ................................ 2-1
Layout of PCBs
and Circuit Diagrams ....................... 3-1 ... 3-14
Block Diagram .............................................................................. 3-1
Wiring Diagram ............................................................................ 3-2
Power Supply ............................................................................... 3-3
Amplifier ....................................................................................... 3-4
Main PCB ..................................................................................... 3-5
CD Section ................................................................................... 3-8
USB Section ............................................................................... 3-11
Display Board/Keyboard ............................................................ 3-13
Exploded View and
Spare Parts List .................................. 4-1 ... 4-2
Exploded View ............................................................................. 4-1
Spare Parts List ........................................................................... 4-2
General Section
Measuring Instruments / Equipment
Signal generator
Oscilloscope
Insulating transformer
General Notes
Before opening the cabinet disconnect the mains plug!
Attention: Observe the ESD safety regulations
Wiring
Before disconnecting any leads and especially the earth connecting
leads observe the way they are routed to the individual assemblies like
the chassis, mains switch panel, keyboard control panel, picture tube
panel, deflection unit, loudspeaker and so on.
On completion of the repairs the leads must be laid out as originally
fitted at the factory to avoid later failures or disturbances.
Carrying out Measurements
When making measurements on semi-conductors with an oscillo-
scope, ensure that the test probe is set to 10:1 dividing factor. If the
previous measurement was made on AC input, please note that the
coupling capacitor in the oscilloscope will be charged. Discharge via
the item being checked can damage the components.
Measured Values
The measured values given in the circuit diagrams are approximates!
1 - 2
VERTIGA UMS 4600 DEC
Page
Sweep generator
Digital voltmeter
Distortion meter

Werbung

loading

Diese Anleitung auch für:

Glr1200