Herunterladen Inhalt Inhalt Diese Seite drucken

Tool Operation - Rehau RAUTOOL M1 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RAUTOOL M1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TOOL OPERATION

Attention risk of injury!
Improper handling of the REHAU tool may result in
personal injury and/or material damage.
- Whenever changing the compression jaw sets, ensure the locking
pins are completely and safely locked into place.
- The battery must be removed from the tool before changing the
compression jaw sets (inadvertent actuation).
- Before each use, check the compression jaw sets, expander bits,
expander sets and the tool for visible damage. Damaged tools must
Expanding tool
Expanding pliers QC:
Fully open the expanding pliers
QC (>90° position) and comple-
tely unscrew the expander heads
and/or lock-in securely using a
bayonet coupling (right-hand ro-
tation). Use QC expander heads
that conform to the pipe dimensi-
ons (for example, 16 x 2.2).
Caution:
Always insert the expander head
fully into the pipe all the way up
to the stop!
not be used and should immediately be sent to an authorised service
centre for repair.
- When inserting the expander bit, always clip the expander bit fully
into the compression jaws.
Expanding device
40 mm pipes are expanded with
the M1 expanding device. The
expanding device is inserted into
the compression jaws M1 40 and
fastened into place with the re-
taining screw.
Before using the tool, check to
make sure the seating is com-
pletely in the clamping jaw and
clamping action of the expanding
device in the clamping jaw are
correct (i.e. to avoid falling out).
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis