2. Channel 2
3. Channel 3

5.3 Outputs

Output is via one 16-pin industrial socket on the rearpanel.
Connect your loads via the pole connectors. The maximum load per channel is 2300 W. Please note that the
maximum current of 60 A must never be exceeded.
The occupation of the 16-pin industrial socket is:

5.4 DMX-512 control

The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the device or one device with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first device in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first device in the DMX-chain with the DMX-input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last device, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last device.
Addressing
Set the required DMX-address via the Control Board.

5.5 Connection with the mains

The electric connection must only be carried out by a qualified electrician!
5. Channel 5
6. Channel 6
the devices will not work at all, or will not work properly.

DANGER TO LIFE!

8. 20 V DC (Output)
18/32
resistor
70064125.DOC