The vibration emission level given in this information sheet
has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with
another. It may be used for a preliminary assessment of expo-
sure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly in-
crease the exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working pe-
riod.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep hands warm, organise work patterns.

Declaration of Conformity

We declare under our sole responsibility that the product de-
scribed under "Technical Data" is in conformity with the fol-
lowing standards or standardization documents: EN 60745
according to the provisions of the directives 2011/65/EU,
2004/108/EC, 2006/42/EC.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen
Dr. Egbert Schneider
Helmut Heinzelmann
Senior Vice President
Head of Product Certification
Engineering
PT/ETM9
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
16.07.2012
Assembly
Before any work on the machine itself, pull the mains
plug.
Auxiliary Handle (see figure A)
Operate your machine only with the auxiliary handle 8.
Before any work, make sure that the wing bolt 7 is firm-
ly tightened. Loss of control can cause personal injury.
The auxiliary handle 8 can be set to any position for a secure
and low-fatigue working posture.
Turn the wing bolt for adjustment of the auxiliary handle 7 in
anticlockwise direction and set the auxiliary handle 8 to the
required position. Then tighten the wing bolt 7 again in clock-
wise direction.
Adjusting the Drilling Depth (see figure A)
The required drilling depth X can be set with the depth stop 9.
Press the button for the depth stop adjustment 6 and insert
the depth stop into the auxiliary handle 8.
2 609 006 496 | (1.8.12)
The knurled surface of the depth stop 9 must face downward.
Pull out the depth stop until the distance between the tip of
the drill bit and the tip of the depth stop correspond with the
desired drilling depth X.
Changing the Tool (see figure B)
Key Type Drill Chuck
Wear protective gloves when changing the tool. The
drill chuck can become very hot during longer work peri-
ods.
Open the key type drill chuck 1 by turning until the tool can be
inserted. Insert the tool.
Insert the chuck key 11 into the corresponding holes of the
key type drill chuck 1 and clamp the tool uniformly.
Screwdriver Tools
When working with screwdriver bits 13, a universal bit holder
12 should always be used. Use only screwdriver bits that fit
the screw head.
For driving screws, always position the "Drilling/Impact Drill-
ing" selector switch 2 to the "Drilling" symbol.
Replacing the Drill Chuck
For power tools without spindle lock, the drill chuck
must be replaced by an authorised after-sales service
agent for Bosch power tools.
The drill chuck must be tightened with a tightening
torque of approx. 30–35 Nm.

Dust/Chip Extraction

Dusts from materials such as lead-containing coatings,
some wood types, minerals and metal can be harmful to
one's health. Touching or breathing-in the dusts can cause
allergic reactions and/or lead to respiratory infections of
the user or bystanders.
Certain dusts, such as oak or beech dust, are considered
as carcinogenic, especially in connection with wood-treat-
ment additives (chromate, wood preservative). Materials
containing asbestos may only be worked by specialists.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filter-class respirator.
Observe the relevant regulations in your country for the
materials to be worked.
Prevent dust accumulation at the workplace. Dusts can
easily ignite.
Operation

Starting Operation

Observe correct mains voltage! The voltage of the pow-
er source must agree with the voltage specified on the
nameplate of the machine. Power tools marked with
230 V can also be operated with 220 V.
Reversing the rotational direction (see figures C–D)
The rotational direction switch 5 is used to reverse the rota-
tional direction of the machine. However, this is not possible
with the On/Off switch 4 actuated.