Following any overfl ow situation reduce the water
level by half and initiate a manual regeneration as
described above.
NB: Check the water level weekly and following
any unplanned event, e.g. powerfailure.

4.3 Setting the hardness of blended water

The unit is preset to 300 ppm.
To test the water hardness, allow the nearest cold
water tap to run for a while and check the hardness
of the blended water using the AQUATEST hard-
ness tester.
Adjust with the blending valve V until the desired
value is reached.
Hard-
No. of people
ness in
ppm
02
03
04
05
150
5
8
7
6
200
5
7
6
4
250
5
3
6
4
300
5
3
2
4
350
3
2
1
4
400
3
2
1
1
= Days between regeneration

5. Maintenance

5.1 Maintenance work

The operator must regularly perform the fol-
lowing checks to guarantee that the unit func-
tions properly.
Check the regenerative and refi ll after use.
Check the water hardness: The hardness of drin-
king water and the set blended water hardness
must be checked 2x annually and the hardness of
the blended water must be corrected when requi-
red (see Start-up).
Check for leaks, visual inspection: Check con-
nection
lines and connections for leaks. Check for dirt in
the regenerative storage area and brine cavity eve-
ry two months and clean and fl ush with clear water
if necessary.
The intervals between checks are recommended
minimums and must be adjusted according to
site conditions.
16
OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd 16-17

5.2 Operator responsibilities

All technical equipment requires regular servicing
in order to guarantee optimal functionality.
Keep yourself up to date with regard to the quality
and pressure ratio of the water which is to be trea-
ted. If the water quality changes, the settings may
need to be changed. Consult a specialist if this is
the case.
Regular checks by the operator are required for
the warranty and proper functioning of the unit. The
water softener must be inspected regularly in ac-
cordance with the conditions of operation and use.
Operator checks intervalls:
After use:
Refi ll regeneration salt
2x Annually:
Check pressure
2x Annually:
Check water quality
06
1x Annually:
Clean brine container
4
3
5.3 Maintenance & wearing parts
2
1
Wearing parts must also be replaced within the
prescribed maintenance intervals in order to
1
guarantee functionality and fulfi l the warranty
1
conditions. The water softener should be serviced
once a year.
Wearing parts may only be replaced by qualifi ed
personnel (fi tters or after-sales service team).
We recommend that you enter into a maintenance
agreement with your fi tter or the aftersales service
team.
Cleaning information: Do not use alcohol or al-
cohol based cleaning agents, otherwise the plastic
surfaces of the device will be damaged.

5.4 Disposal

At the end of product life
please contact Cillit
Customer
®
Services to arrange a new
replacement for your softener.
Disposal of your softener and any electrical parts
should only be carried out at authorised WEEE
recycling centres.
6. Fault fi nding

6.1 Trouble shooting Guide

Attention:
If your water softener is not performing as it should, please run through the check
list below.
Checklist
Solution
Problem: Water still remains hard.
Is there a minimum of 150mm of salt in
Fill the brine cabinet with salt.
the brine cabinet?
Is the power on?
Switch the power on and check connections.
Is the softener online?
Close the by-pass valve and open the inlet
and outlet valves.
Is the hardness setting correct?
Reset the hardness if required.
Problem: Water level in brine cabinet
reaches overfl ow.
Is the line pressure within the specifi ca-
Connect a pressure gauge to a water outlet
tion of the water softener?
and check the pressure is between: 1.7 - 5.0
bar for the UK / 1.0 - 8.0 bar for EU.
Pressure falls outside of the water
Fit a pressure reducing valve or booster
softener specifi cation.
pump as required. (see note below)
Is there fl ow through the drain line?
Check the drain line is not kinked, blockedor
frozen.
Has there been a power interruption?
Check that the power is on and the connec-
tions are secure.
Problem: No water.
Is the mains stop valve open?
Open the mains stop valve.
Are the inlet and outlet valves of the
Open the inlet and outlet valves to the water-
water softener open?
softener.
Note:
If any overfl ow situation occurs or if any of the above requires action reduce the
water level by half and initiate a regeneration by pressing and holding the manual
regeneration key [RECHARGE] for more than six seconds.
EN
Page
13
13
13
7, 13, 16
8, 9
8, 9
11, 12
8, 13, 14
11, 13
11, 13
17
02/10/2012 09:49

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis