EN

2. Quick Operation

2.1 Display and control elements

Note: In the programming
mode the respective
>target value< flash.
[UP]
[DOWN]
= Moves cursor changes entries

2.2 Standard factory settings

Operating range:
depends on model
Regeneration time:
free input at RECHARGE TONIGHT
Hardness of drinking water / capacity:
300 ppm, 1566 litres for 10 litre model
Cillit
®
Access
Standard
Display
Yes
Operating range
UK/EU
Recharge tonight
Yes
Salt alarm
No
Salt setting - care cubes (CC)
UK/EU
Salt setting - block salt (BS)
UK only
6
OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd 6-7
The display shows:
the current time and
the remaining
capacity in %
[SET]
[RECHARGE]
= Programming
= Confirms entries
recharge tonight
BIO
UK
EU
Yes
Yes
Yes
UK/EU
1.7 ... 5.0 bar
1.0 ... 8.0 bar
Yes
Yes
Yes
No
OPTION
OPTION
UK/EU
Yes
Yes
UK only
No
Yes

2.3 Programming procedure

1. Setting the time of day (see Fig. 1)
The first two digits (00) of the display will flash
prompting the installer to set the time.
7
The time is adjusted by using the [UP], [DOWN]
keys. Pressing the [SET] key enters the hours.
The minutes are set by using the [UP], [DOWN]
keys.
Pressing the [SET] key once enters the minutes
and moves the display into the Set Hardness mode.
2. Setting the water hardness (see Fig. 2)
The display default is 300 ppm (typical hardness
level) which indicates a setting suitable for hard
water with a value of 300 parts per million of hard-
ness minerals. Use the keys [UP] [DOWN] keys
to adjust the setting to match that of the one you
obtained / identified earlier. See page 6 for details.
Pressing the [SET] set key once enters the hard-
ness and moves the display to Set Recharge Time
Mode.
3. Setting the recharge time (see Fig. 3)
To operate effectively, your water softener needs
to regenerate periodically (dependent on the hard-
ness of the supply and amount of water used). The
default time of day when this is to occur is 2.00am.
To alter this setting use the [UP] [DOWN] keys.
Pressing the [SET] key once enters the rechar-
ge time and moves the display into Set Salt Type
Mode.
This option is only
available on certain
models - not standard
02/10/2012 09:48