Nominal connection (outside thread)
Nominal fl ow rate in accordance with EN 14743
Operating pressure EU (min./max.)
Operating pressure UK (min./max.)
Pressure drop down at nominal fl ow in accordance
with EN 14743
Quantity of ion exchange resin
Nominal capacity (EN 14743) / (CaCO3 mmol/l)
Capacity salt reservoir
Salt consumption per regeneration
Water consumption per regeneration
Protection class
Water temperature (min./max.)
Ambient temperature (min./max.)
Electrical connection
Dimensions: Width x depth x height (W x D2 x H)
Connection height (A) / overfl ow height (S)
Operating weight, approx.
*Tested with HiFlow connection available in option
D
1
D
2
22
OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd 22-23
Unit
25 / 25 Bio
BSP
¾" (DN 20)
l/h
1680
bar
1.0 / 8.0
bar
1.7 / 5.0
bar
1.0
25
l
m³x°dH/mol/ppm
75 / 13.4 / 1340
kg
24
kg
3.0
145
l
IP
51
°C
5 / 30
°C
5 / 40
V / Hz
230 / 50
mm
270 x 480 x 804
mm
675 / 540
kg
70
W

EC declaration of incorporation *

BWT UK Ltd.
Coronation Road, BWT House
High Wycombe
Buckinghamshire, HP12, 3SUH
The company
declares that the product
BWT UK Ltd.
with the following specifi cations:
Type of product Model
Trade name of product
• Cillit
®
Access
10 / 10 BIO
• Cillit
®
Access
15 / 15 BIO
• Cillit
®
Access
20 / 20 BIO
• Cillit
®
Access
25 / 25 BIO
with a serial number higher than:
and with a production- and reference no.:
have been
and
designed, manufactured
assembled according
EC Directives (guidelines):
Guideline for low voltage (LVD)
2006/95/EC
Guideline for electromagnetic compatibility (EMC)
2004/108/EC
Do not perform any changes, extension and reconstruction work on the device which might impair
Note:
safety without the approval of BWT UK Ltd., otherwise this declaration loses its validity.
Please ensure that all conditions of the
Note:
installation preconditions
th
Buckinghamshire, 30
May 2011
Ian Threadgill
General Manager (Supply Chain)
BWT UK Ltd. – Coronation Road – Buckinghamshire, HP12, 3SUH
Manufacturer:
) Machinery Directive 2006/42/EC annex II, part II, part A, par. B
*
)
domestic water softener
10 litres
15 litres
20 litres
25 litres
1105 000101
see rating plate & technical specifi cations
to the following
are met!