Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Cillit Access 10 / 10 Bio - Cillit Access 10 Einbau- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
Attention:
If your water softener is not performing as it should, please run through the check
list below.
Checklist
Solution
Problem: Water runs from the drain
constantly.
Is the unit in recharge mode?
If yes, this is normal, wait until the recharge
is complete.
Is the power on?
There should be no fl ow to drain in the ser-
vice position.
Problem: Excessive salt usage.
Check the hardness setting.
Reduce the hardness if incorrect.
Problem: Electronic Display.
The display shows error code: "Err
Check all the connections are secure. Turn
1", audible alarm sounds, (see note
the power off for 10 seconds then turn back
below).
on, allow the system to reset.
OPTIONAL: The display shows error
The low salt alarm is active. Fill the brine
code:"SALt", audible alarm sounds.
cabinet with salt. Pressing the [SET] key will
reset the salt alarm to full capacity of salt.
Is the digital display blank?
Check the power is turned on and all thecon-
nections are secure.
Problem: Unit regenerates at the wrong
time.
Is the present time correct?
Reset the present time.
Note:
If the home position is not detected within 10 minutes, the main display will show
an "Err 1" message to indicate a controller error and an audible alarm will sound.
The error condition can only be cleared by removing and re-applying the power.
Attention:
If problem persists, please call your local dealer or after sales service team.
18
OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd 18-19

7. Technical data

®
7.1 Cillit
Access 10 / 10 Bio*
Cillit
®
Access
Nominal connection (outside thread)
Page
Nominal fl ow rate in accordance with EN 14743
Operating pressure EU (min./max.)
Operating pressure UK (min./max.)
7
Pressure drop down at nominal fl ow in accordance
with EN 14743
Quantity of ion exchange resin
8
Nominal capacity (EN 14743) / (CaCO3 mmol/l)
Capacity salt reservoir
Salt consumption per regeneration
7, 16
Water consumption per regeneration
Protection class
13
Water temperature (min./max.)
Ambient temperature (min./max.)
Electrical connection
15
Dimensions: Width x depth x height (W x D2 x H)
Connection height (A) / overfl ow height (S)
Operating weight, approx.
13
*Tested with HiFlow connection available in option
7
Unit
BSP
l/h
bar
bar
bar
l
m³x°dH/mol/ppm
kg
kg
l
IP
°C
°C
V / Hz
mm
mm
kg
D
1
D
2
EN
10 / 10 Bio
¾" (DN 20)
1440
1.0 / 8.0
1.7 / 5.0
1.0
10
26 / 4.6 / 460
12
1.5
85
51
5 / 30
5 / 40
230 / 50
270 x 480 x 532
403 / 270
40
W
19
02/10/2012 09:49

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis