Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha DM2000 Bedienungsanleitung Seite 351

Vorschau ausblenden Andere Handbücher für DM2000:
Inhaltsverzeichnis

Werbung

When this is received, the corresponding effect's function activates (de-
pending on the effect type).
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
00000110 7F
Function call Event
ADDRESS
00010010 12
Function
0000aaaa 0a
-
DATA
00000000 00
Release:0, Press:1
0ddddddd dd
-
00000000 00
Destination Effect Number 0 - 7
0ddddddd dd
End of exclusive
EOX
11110111 F7
function
Freeze Play button
Freeze Record button
Auto Pan 5.1 Trigger Button
Auto Pan 5.1 Reset Button
• This does not activate when the effect type is different.
12.3.20 Parameter change (Key remote)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the same processing that is executed when the key
specified by Address is pressed (released). (Refer to the PARAMETER
CHANGE PARAMETER NUMBER LIST.)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Address UU
ADDRESS
00100000 20
Address UL
0aaaaaaa aa
Address LU
0aaaaaaa aa
Address LL
0aaaaaaa aa
0:press, 1:release
DATA
0ddddddd dd
End of exclusive
EOX
11110111 F7
12.3.21 Parameter change (Remote Meter)
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50 msec for 10 seconds.
When you want to transmit meter information continuously, a Request
must be transmitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified
by Address (see PARAMETER CHANGE PARAMETER NUMBER LIST)
will be transmitted on the [Rx CH] channel at 50 msec intervals for a du-
ration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Address UU
ADDRESS
00100001 21
Address UL
0aaaaaaa aa
Address LU
0aaaaaaa aa
Address LL
0aaaaaaa aa
Data1 H
DATA
0ddddddd dd
Channel
0x00
0:Effect1-7:Effect8
0x01
0:Effect1-7:Effect8
0x02
0:Effect1-1:Effect2
0x03
0:Effect1-1:Effect2
Format Details
Data1 L
0ddddddd dd
:
End of exclusive
EOX
11110111 F7
Meter data uses the unmodified DECAY value of the DSP. For the inter-
pretation of the value, refer to the PARAMETER CHANGE PARAMETER
NUMBER LIST.
12.3.22 Parameter request (Remote Meter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the parameter specified by Address (refer to PA-
RAMETER CHANGE PARAMETER NUMBER LIST) will be transmitted
on the [Rx CH] at 50 msec intervals for a duration of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Address UU
ADDRESS
00100001 21
Address UL
0aaaaaaa aa
Address LU
0aaaaaaa aa
Address LL
0aaaaaaa aa
Count H
DATA
0cccccccccc
Count L
0ccccccccCc
End of exclusive
EOX
11110111 F7
12.3.23 Parameter change (Remote Time Counter)
When transmission is enabled by receiving a Request of Remote Time
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Remote Time Counter
ADDRESS
00100001 22
0:Time Code, 1: Measure, Beat, Clock
0000tttt 0t
Hour / Measure H
DATA
0ddddddd dd
Min / Measure L
0ddddddd dd
Sec / Beat
0ddddddd dd
Frame / Clock
0ddddddd dd
End of exclusive
EOX
11110111 F7
12.3.24 Parameter request (Remote Time Counter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the Time Counter information is transmitted on the
[Rx CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission
will be halted immediately.
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
DM2000—Bedienungsanleitung
337

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis