Instruction on mounting and use
Consult the designs in the front pages referenced in the text by
alphabet letters. Closely follow the instructions set out in
this manual. All responsibility,
inconveniences, damages or fires caused by not complying
with the instructions in this manual, is declined.
Use
The hood is designed to be utilized either for suction version at
external evacuation or filtering version at internal recirculation.
Ducting version
The hood is equipped with a top air outlet B for discharge of
fumes to the outside (exhaust pipe and pipe fixing clamps not
provided). Attention!
If the hood is supplied with carbon filter, then it must be
removed.
Filter version
When there is no exhaust duct for venting outdoors, you can
use a carbon filter.
The air is depurated by the filter and put again in the
surrounding. To use the appliance in this version, proceded as
follows:
The air is vented outdoors by a duct, passing througt the wall
units and connected to the connecting ring.
Attention!
If the hood is not supplied with carbon filter, then it must
be ordered and mounted.
Important:
For the 74,8 cm hood (Fig. 6-7)
Before using the hood, ensure that the inside grids (G-Fig.
8)are open (Exhaust mode) or closed (Filter version).

Installation

The minimum distance between the supporting surface for the
cooking vessels on the hob and the lowest part of the range
hood must be not less than 65cm from electric cookers and
75cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
Th
e electrical tension must correspond to the tension noted on
the label placed inside the cooker hood. Connect the electrical
plug, where provided, to the an easily accessible outlet in
conformity with local standards in force. Where an electrical
plug is not provided (for direct connection to electrical network)
place a standards approved bipolar switch with an aperture
distance of not less than 3mm (accessible) from the contacts.
Attention: substituting the supply cable must be carried out by
the authorised technical assistance service.
for any eventual
7
Electric connection (ONLY for UK)
WARNING:
THIS APPLIANCE MUST BE EARTHED
The mains lead of this appliance is fitted with a BS 1363 5
amp fused plug.
To change a fuse in this type of plug use an A.S.T.A.
approved fuse to BS1362 type.
1. Remove the fuse cover and fuse .
2. Fit replacement 5A fuse into fuse cover.
3. Refit both into plug.
IMPORTANT: The fuse cover must be refitted when
changing a fuse and if the fuse cover is lost the plug must not
be used until a correct replacement is fitted.
Correct replacements are identified by the colour insert or the
colour embossed in words on the base of the plug.
Replacement fuse covers are available from your local
Electricity Board Shop.
HOW TO CONNECT AN ALTERNATIVE PLUG
If the fitted plug is not suitable for your socket outlet, then it
should be cut off and disposed of in order to avoid a possible
shock hazard should it be inserted into a 5A socket
elsewhere.
A suitable alternative plug of at least 5 Amp rating e.g. 5 Amp
round pin to BS 546 should then be fitted to the cable.
The wires in this mains lead are coloured in accordance with
the following code:-
BLUE – "NEUTRAL" - "N"
BROWN – "LIVE" - "L"
GREEN AND YELLOW – "EARTH" - "E"
1
The GREEN AND YELLOW wire must be connected to
the terminal in the plug which is marked with the letter
"F" or by the Earth symbol
green and yellow.
2
The BLUE wire must be connected to the terminal which
is marked with the letter "N" or coloured black.
3
The BROWN wire must be connected to the terminal
which is marked with the letter "L" or coloured red.
Mounting
Expansion wall plugs are provided to secure the hood to
most types of walls/ceilings. However, a qualified technician
must verify suitability of the materials in accordance with the
type of wall/ceiling. The wall/ceiling must be strong enough to
take the weight of the hood. Do not tile, grout or silicone
this appliance to the wall. Surface mounting only.
This hood is designed for fitting in a cabinet or on some other
support.
Description of the hood