Installation - Jøtul I 350 Montageanleitung Mit Technischen Daten

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
ENGLISH
Wood consumption
Jøtul I 350/I 350 FL has a nominal heat output of 8,0 kW.
Use of wood, with nominal heat emission: Approx. 2,6 kg/h.
Another important factor for proper fuel consumption is that
the logs are the correct size. The size of the logs should be:
Kindling:
Length: Approx 30 cm
Diameter: 2-5 cm
Amount per fire: 8 - 10 pieces
Firewood (split logs):
Recomended length: 30-35 cm
Diameter: Approx. 8 - 12 cm
Intervals for adding wood: Approximately every 45 minutes
Size of the fire: 2,0 kg
Mengde pr. ilegg: 3 stk.
Nominal heat emission is achieved when the air vent is open
approximately 50% (fig. 6B).
16

3.0 Installation

3.1 Floor
Foundations
It must be ensured that the foundations are dimensioned for
the fireplace. Cf. «2.0 Technical data» for specification of weight.
It is recommended that flooring which is not fastened to the
foundations – so-called floating flooring – is removed during
installation.
Requirements for protection of wooden flooring
The product can be placed directly on a wooden floor that is
covered by a metal plate or other suitable, non-inflammable
material. The recommended minimum thickness is 0.9 mm.
Any flooring made of combustible material, such as linoleum,
carpets, etc. must be removed from under the floor plate.
Requirement for protecting combustible flooring
in front of fireplace
The front plate must be in accordance with national laws and
regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.2 Wall
Distance to walls made of combustible material -
see fig. 1
Requirements for insulation
80 mm rock wool 120 kg/m
aluminium.
Distance from the stove to the insulation on the back panel.
See fig. 1 and 2:
Minimum 15 mm.
Distance to walls protected by a firewall-see fig. 1
Firewall requirement
The firewall must be at least 100 mm thick and be made of
brick, concrete-stone or light concrete. Other materials and
structures with satisfactory documentation may also be used.
Contact your local building authorities regarding restrictions and
installation requirements.
Distance from the stove to firewall:
The distance must be minimum 15 mm.
Distance to non combustible wall -see fig. 1
A non combustible wall is here mentioned as a non load-bearing
wall of cement /brick.