Rigging

When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
The device can be installed on the ground or on the wall or ceiling.
The mounting location of the LED LT-100 must be chosen in such a way that any accidental damages or
those occuring through vandalism are excluded. This is also the case when mounted with the enclosed
mounting brackets. When mounting this device with brackets, any mechanical tension from the brackets
must not be transfered to the stick.
For public areas, the respective valid accident prevention regulations must be respected. The LED LT-100
must be installed out of the reach of people. Overhead installation is only allowed when additional safety
measures are taken.
If the LED LT-100 shows any kind of inner or outer damage, for example deep scratches, splintered tube or
cable/plug damage, then any further use is forbidden. If the LED LT-100 shows any kind of damage during
use, then the stick must not be touched and must be disconnected from the mains as well as unplugged from
the mains socket. A damaged LED LT-100 must not be repaired with tape or similar resources. It must be
either disposed of according to local environmental regulations or taken to a professional for repairs.
Allowed temperature range is between -5° C und +45° C. Maximal allowed atmospheric humidity is 75% rel.
humidity (not condensed).

Hanging installation

Please consider the EN 60598-2-17 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all

DANGER OF FIRE!

DANGER TO LIFE!